f.
In the first 'Proxy Address' field, enter the IP address and port of the device (in
the format x.x.x.x:port). This is the port as defined in the 'SAS Local
UDP/TCP/TLS Port' field (see 'Configuring Common SAS Parameters' on page
499).
Figure ‎ 3 2-4: Defining Proxy Server for Gateway Application
g.
Click Submit.
2.
Disable use of user=phone in SIP URL:
a.
Open the SIP General Parameters page (Configuration tab > VoIP menu > SIP
Definitions submenu > General Parameters).
b.
From the 'Use user=phone in SIP URL' drop-down list, select No. This instructs
the Gateway application not to use user=phone in the SIP URL and therefore,
REGISTER and INVITE messages use SIP URI. (By default, REGISTER
messages are sent with sip uri and INVITE messages with tel uri.)
c.
Click Submit.
User's Manual
Figure ‎ 3 2-5: Disabling user=phone in SIP URL