15
Touch Probe Cycles: Automatic Presetting | PRESET CIRCLE CENTER (Cycle 416, DIN/ISO: G416)

Cycle parameters

Q273 Center in 1st axis (nom. value)? (absolute):
Bolt hole circle center (nominal value) in the
reference axis of the working plane. Input range
-99999.9999 to 99999.9999
Q274 Center in 2nd axis (nom. value)?
(absolute): Bolt hole circle center (nominal value)
in the minor axis of the working plane. Input range
-99999.9999 to 99999.9999
Q262 Nominal diameter?: Enter the approximate
bolt hole circle diameter. The smaller the hole
diameter, the more exact the nominal diameter
must be. Input range -0 to 99999.9999
Q291 Polar coord. angle of 1st hole? (absolute):
Polar coordinate angle of the first hole center
in the working plane. Input range -360.0000 to
360.0000
Q292 Polar coord. angle of 2nd hole? (absolute):
Polar coordinate angle of the second hole center
in the working plane. Input range -360.0000 to
360.0000
Q292 Polar coord. angle of 3rd hole? (absolute):
Polar coordinate angle of the third hole center
in the working plane. Input range -360.0000 to
360.0000
Q261 Measuring height in probe axis? (absolute):
Coordinate of the ball tip center (= touch point) in
the touch probe axis in which the measurement
is to be made. Input range -99999.9999 to
99999.9999
Q260 Clearance height? (absolute): coordinate in
the touch probe axis at which no collision between
tool and workpiece (fixtures) can occur. Input
range -99999.9999 to 99999.9999
Q305 Number in table?: Specify the row number
of the preset table/datum table to which the TNC
saves the coordinates of the center point; input
range 0 to 9999. The TNC writes the entry to the
preset table or datum table depending on Q303:
Q303 = 1:
If the active preset is modified this change
immediately becomes effective. Otherwise an
entry is made in the specific row of the preset
table without automatic activation
Q303 = 0:
datum is not automatically activated
Q331 New preset in reference axis? (absolute):
Coordinate in the reference axis at which the
TNC should set the bolt hole circle center.
Default setting = 0. Input range -99999.9999 to
99999.9999
568
The TNC writes to the preset table.
The TNC writes to the datum table. The
NC blocks
5 TCH PROBE 416 PRESET CIRCLE
CENTER
Q273=+50
;CENTER IN 1ST AXIS
Q274=+50
;CENTER IN 2ND AXIS
Q262=90
;NOMINAL DIAMETER
Q291=+34
;ANGLE OF 1ST HOLE
Q292=+70
;ANGLE OF 2ND HOLE
Q293=+210
;ANGLE OF 3RD HOLE
Q261=-5
;MEASURING HEIGHT
Q260=+20
;CLEARANCE HEIGHT
Q305=12
;NUMBER IN TABLE
Q331=+0
;PRESET
Q332=+0
;PRESET
Q303=+1
;MEAS. VALUE TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+85
;1ST CO. FOR TS AXIS
Q383=+50
;2ND CO. FOR TS AXIS
Q384=+0
;3RD CO. FOR TS AXIS
Q333=+1
;PRESET
Q320=0
;SET-UP CLEARANCE
HEIDENHAIN | User's manual for cycle programming | 10/2017