Cycle Parameters - HEIDENHAIN TNC 640 User Manual

Hide thumbs Also See for TNC 640:
Table of Contents

Advertisement

17

Cycle parameters

Parameter number for result?Enter the number
of the Q parameter to which you want the TNC
to assign the first measured coordinate (X). The
values Y and Z are in the immediately following Q
parameters. Input range 0 to 1999
Relative measuring path in X?: X component
of the direction vector defining the direction in
which the touch probe is to move. Input range
-99999.9999 to 99999.9999
Relative measuring path in Y?: Y component
of the direction vector defining the direction in
which the touch probe is to move. Input range
-99999.9999 to 99999.9999
Relative measuring path in Z?: Z component
of the direction vector defining the direction in
which the touch probe is to move. Input range
-99999.9999 to 99999.9999
Maximum measuring range?: Enter the maximum
distance from the starting point by which the
touch probe may move along the direction vector.
Input range -99999.9999 to 99999.9999
Feed rate measurement: Enter the measuring
feed rate in mm/min. Input range 0 to 3000.000
Maximum retraction distance?: Traverse path
in the direction opposite the probing direction,
after the stylus was deflected. Input range 0 to
99999.9999
Reference system? (0=ACT/1=REF): Specify
whether the result of probing is to be saved in the
input coordinate system (ACT), or with respect to
the machine coordinate system (REF):
0: Save measuring result to the ACT system
1: Save measuring result to the ref system
634
Touch Probe Cycles: Special Functions | MEASURING IN 3-D (Cycle 4)
HEIDENHAIN | User's manual for cycle programming | 10/2017
NC blocks
4 TCH PROBE 4.0 MEASURING IN 3-D
5 TCH PROBE 4.1 Q1
6 TCH PROBE 4.2 IX-0.5 IY-1 IZ-1
7 TCH PROBE 4.3 ABST+45 F100 MB50
REFERENCE SYSTEM:0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 640 e

Table of Contents