13.3 Touch probe table

General information

Various data is stored in the touch probe table that defines the
probe behavior during the probing process. If you use several touch
probes on your machine tool, you can save separate data for each
touch probe.
You can also view and edit the data of the touch probe
table in the expanded tool management (option 93).

Editing touch probe tables

To edit the touch probe table, proceed as follows:
Mode of operation: Press the Manual operation
key
Select the touch probe functions: Press the
TOUCH PROBE soft key. The TNC displays
additional soft keys
Select the touch probe table: Press the
TCH PROBE TABLE soft key
Set the EDIT soft key to ON
Using the arrow keys, select the desired setting.
Perform desired changes.
Exit the touch probe table: Press the END soft
key