18

Monitoring phase

The monitoring phase starts as soon as the TNC has generated
enough reference images.
Cycle run: Monitoring phase
1 The camera will be mounted by the machine tool builder onto
the main spindle.
2 The TNC automatically opens the camera lid.
3 The TNC will generate an image of the current condition.
4 There is then an image comparison between the mean
image and the variance image (for more information, See
"Fundamentals", page 656)
5 Depending on whether the TNC detects an "error" (deviation),
the TNC can now force a program cancellation (for for further
information, "Results of the image evaluation"). If parameter
Q309=1 is set, the TNC will display the image on the screen
upon detecting an error. If parameter Q309=0 is set, no image
will be displayed on the screen and the program will not be
stopped.
6 Depending on parameter Q613, the TNC either leaves the
camera lid open or closes it.
676