10
Cycles: Coordinate Transformations | DATUM SHIFT with datum tables (Cycle 7, DIN/ISO: G53)

Configuring a datum table

If you do not wish to define a datum for an active axis, press
the DEL key. Then the TNC clears the numerical value from the
corresponding input field.
You can change the properties of tables. Enter the code
number 555343 in the MOD menu. The TNC then offers
the EDIT FORMAT soft key if a table is selected. When
you press this soft key, the TNC opens a pop-up window
where the properties are shown for each column of the
selected table. Any changes made only affect the open
table.

Leaving a datum table

Select a different type of file in file management and choose the
desired file.
Danger of collision!
The control considers changes in a datum table only when the
values are saved.
Confirm changes in the table immediately with the ENT key
Carefully test the NC program after making a change to the
datum table

Status displays

In the additional status display, the TNC shows the values of the
active datum shift.