15
Touch Probe Cycles: Automatic Presetting | PRESET FROM INSIDE OF CIRCLE (Cycle 412, DIN/ISO: G412)

Cycle parameters

Q321 Center in 1st axis? (absolute): Center of the
pocket in the reference axis of the working plane.
Input range -99999.9999 to 99999.9999
Q322 Center in 2nd axis? (absolute): Center of
the pocket in the minor axis of the working plane.
If you program Q322 = 0, the TNC aligns the hole
center to the positive Y axis. If you program Q322
not equal to 0, then the TNC aligns the hole center
to the nominal position. Input range -99999.9999
to 99999.9999
Q262 Nominal diameter?: Approximate diameter
of the circular pocket (or hole). Enter a value that
is more likely to be too small than too large. Input
range 0 to 99999.9999
Q325 Starting angle? (absolute): Angle between
the reference axis of the working plane and the
first touch point. Input range -360.000 to 360.000
Q247 Intermediate stepping angle?
(incremental): Angle between two measuring
points. The algebraic sign of the stepping
angle determines the direction of rotation
(negative = clockwise) in which the touch probe
moves to the next measuring point. If you wish to
probe a circular arc instead of a complete circle,
then program the stepping angle to be less than
90°. Input range -120.000 to 120.000
Q261 Measuring height in probe axis? (absolute):
Coordinate of the ball tip center (= touch point) in
the touch probe axis in which the measurement
is to be made. Input range -99999.9999 to
99999.9999
Q320 Set-up clearance? (incremental): Define
an additional distance between measuring point
and ball tip. Q320 is added to SET_UP in the touch
probe table. Input range 0 to 99999.9999
Q260 Clearance height? (absolute): coordinate in
the touch probe axis at which no collision between
tool and workpiece (fixtures) can occur. Input
range -99999.9999 to 99999.9999
548
NC blocks
5 TCH PROBE 412 PRESET INSIDE CIRCLE
Q321=+50
;CENTER IN 1ST AXIS
Q322=+50
;CENTER IN 2ND AXIS
Q262=75
;NOMINAL DIAMETER
Q325=+0
;STARTING ANGLE
Q247=+60
;STEPPING ANGLE
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q305=12
;NUMBER IN TABLE