Cycle Parameters - HEIDENHAIN TNC 640 User Manual

Hide thumbs Also See for TNC 640:
Table of Contents

Advertisement

16
Touch Probe Cycles: Automatic Workpiece Inspection | MEASURE HOLE OUTSIDE (Cycle 422, DIN/ISO:

Cycle parameters

Q273 Center in 1st axis (nom. value)? (absolute):
Center of the stud in the reference axis of the
working plane. Input range -99999.9999 to
99999.9999
Q274 Center in 2nd axis (nom. value)?
(absolute): Center of the stud in the minor axis
of the working plane. Input range -99999.9999 to
99999.9999
Q262 Nominal diameter?: Enter the diameter of
the stud. Input range 0 to 99999.9999
Q325 Starting angle? (absolute): Angle between
the reference axis of the working plane and the
first touch point. Input range -360.000 to 360.000
Q247 Intermediate stepping angle?
(incremental): Angle between two measuring
points. The algebraic sign of the stepping angle
determines the direction of rotation (negative
= clockwise). If you wish to probe a circular arc
instead of a complete circle, then program the
stepping angle to be less than 90°. Input range
-120.0000 to 120.0000
Q261 Measuring height in probe axis? (absolute):
Coordinate of the ball tip center (= touch point) in
the touch probe axis in which the measurement
is to be made. Input range -99999.9999 to
99999.9999
Q320 Set-up clearance? (incremental): Define
an additional distance between measuring point
and ball tip. Q320 is added to SET_UP in the touch
probe table. Input range 0 to 99999.9999
Q260 Clearance height? (absolute): coordinate in
the touch probe axis at which no collision between
tool and workpiece (fixtures) can occur. Input
range -99999.9999 to 99999.9999
Q301 Move to clearance height (0/1)?: Definition
of how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
602
NC blocks
5 TCH PROBE 422 MEAS. CIRCLE
OUTSIDE
Q273=+50
;CENTER IN 1ST AXIS
Q274=+50
;CENTER IN 2ND AXIS
Q262=75
;NOMINAL DIAMETER
Q325=+90
;STARTING ANGLE
Q247=+30
;STEPPING ANGLE
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+10
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q277=35.15;MAXIMUM LIMIT
Q278=34.9
;MINIMUM LIMIT
HEIDENHAIN | User's manual for cycle programming | 10/2017