12
Cycle parameters
Q450 Max. permissible runout? Specifies the
maximum runout of a sinusoidal unbalance signal
in millimeters (mm). The signal results from the
following error of the measuring axis and from the
spindle revolutions.
Q451 Rotational speed? Input in revolutions per
minute (rpm). The test for an unbalance begins
with a low initial speed (e.g. 50 rpm). It is then
automatically increased by specified increments
(e.g. 25 rpm). The speed is increased until the
speed defined in Parameter Q451 is achieved.
Spindle speed override is disabled.
486
Cycles: Turning | CHECK UNBALANCE (Cycle 892, DIN/ISO: G892)
HEIDENHAIN | User's manual for cycle programming | 10/2017
NC blocks
63 CYCL DEF 892 CHECK IMBALANCE
Q450=0
;MAXIMUM RUNOUT
Q451=50
;SPEED