18

Cycle parameters

QS600 (string parameter) Name of monitoring
point?: Enter the name of your monitoring file
Q309 PGM stop if tolerance exceeded?: (0/1)
Specify whether the TNC stops the program if an
error is detected.
0:
Even if not all reference images have been
generated yet, no stop is performed. This means
that the generated image will not be displayed on
the screen. Parameter Q601 is written to even if
Q309=0.
1:
the generated image will be displayed in the
screen. If not enough reference images have been
generated yet, every new image will be displayed
on the screen until the TNC has generated enough
reference images. If an error is detected, the TNC
will display a message.
Q613 Keep camera cap open?: (0/1) Specify
whether the TNC should keep the camera cap
open after monitoring.
0: The TNC closes the camera cap after running
Cycle 601.
1: The TNC keeps camera cap open after running
Cycle 601. This function is only recommended if
you would like to generate yet another image of
the workspace in a different position after the first
cycle call of Cycle 601. In order to so, program
the new position on a straight line block and then
call up Cycle 601 with a new monitoring point.
Program Q613=0 before continuing with the
cutting operation!
Q617 Number of reference images?: Number of
reference images that are required by the TNC for
monitoring.
678
Visual Setup Control VSC (Software Option 136) | Workspace Local (Cycle 601)
Program does not stop if an error is detected.
Program will stop after detecting an error,
NC blocks
4 TCH PROBE 601 WORKSPACE LOCAL
QS600="OS"
;MONITORING POINT
Q309=+1
;PGM STOP IF ERROR
Q613=0
;KEEP CAMERA OPEN
Q617=10
;REFERENCE IMAGES
HEIDENHAIN | User's manual for cycle programming | 10/2017