Measure Kinematics (Cycle 451, Din/Iso: G451, Option); Cycle Run - HEIDENHAIN TNC 640 User Manual

Hide thumbs Also See for TNC 640:
Table of Contents

Advertisement

19
Touch Probe Cycles: Automatic Kinematics Measurement | MEASURE KINEMATICS (Cycle 451, DIN/ISO:
19.4 MEASURE KINEMATICS (Cycle 451, DIN/
ISO: G451, option)

Cycle run

Touch Probe Cycle 451 enables you to check and, if required,
optimize the kinematics of your machine. Use the 3-D TS touch
probe to measure a HEIDENHAIN calibration sphere that you have
attached to the machine table.
HEIDENHAIN recommends using the calibration
spheres
100 (ID number 655
high rigidity and are designed especially for machine
calibration. Please contact HEIDENHAIN if you have any
questions in this regard.
The TNC evaluates the static tilting accuracy. The software
minimizes the spatial error arising from the tilting movements and,
at the end of the measurement process, automatically saves the
machine geometry in the respective machine constants of the
kinematics description.
1 Clamp the calibration sphere and check for potential collisions.
2 In the Manual Operation mode, set the preset in the center
of the sphere or, if Q431=1 or
position the touch probe over the calibration sphere in the touch
probe axis, and in the center of the sphere in the working plane.
3 Select the Program Run mode and start the calibration program.
4 The TNC automatically measures all three axes successively in
the resolution you defined.
5 The TNC saves the measured values in the following Q
parameters:
686
KKH 250
(ID number 655 475-01) or
475-02), which have particularly
Q431=3
is defined: Manually
KKH
HEIDENHAIN | User's manual for cycle programming | 10/2017
G451, option)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 640 e

Table of Contents