Danger of collision!
Cycles for coordinate transformation must not be active during
execution of the touch probe cycles.
Do not activate the following cycles before using touch probe
cycles: Cycle 7 DATUM SHIFT,Cycle 8 MIRROR IMAGE, Cycle
10 ROTATION,Cycle 11 SCALING and 26 AXIS-SPECIFIC
SCALING
Reset any coordinate transformations beforehand
The control must be specially prepared by the machine
tool builder for the use of a 3-D touch probe.
HEIDENHAIN only gives warranty for the function of the
probing cycles if HEIDENHAIN touch probes are used.
The TNC provides five cycles that enable you to measure and
compensate workpiece misalignment. In addition, you can reset a
basic rotation with Cycle 404: