19
Touch Probe Cycles: Automatic Kinematics Measurement | KINEMATICS GRID (Cycle 453, DIN/ISO: G453,

Various modes (Q406)

Delete mode Q406 = -1
The axes are not moved
The TNC writes all values to the compensation table (*kco) with
"0". This results in no further compensations to the momentarily
selected kinematics
Test mode Q406 = 0
The TNC performs probe measurements on the calibration
sphere.
The results are saved to a protocol with .html format. This
protocol is stored in the same directory as the current program
Compensate mode Q406 = 1
The TNC performs probe measurements on the calibration sphere
The TNC writes the deviations to the compensation table (*kco).
The table is updated, the compensations are immediately
effective
The results are saved to a protocol with .html format. This
protocol is stored in the same directory as the current program
Choice of the calibration sphere position on the
machine table
In principle, you can fix the calibration sphere to any accessible
position on the machine table and also on fixtures or workpieces.
It is recommended to clamp the calibration sphere as closely as
possible to the position intended for subsequent machining.