12. Go to the operators compartment and locate
the vacuum head adjustment knob. Remove
the adjustment knob.
13. Remove the clevis pin holding the propel
pedal to the pivot bracket. Position the
propel pedal back out of the way of the
vacuum head cable assembly mount plate.
14. Remove the three hex screws holding the
slide assembly to the cable assembly mount
plate. Remove the slide assembly from the
machine.
15. Remove the three hex screws holding the
vacuum head cable assembly mount plate to
the machine (one on top, two from under
front of frame).
16. Pull the vacuum head cable assembly mount
plate back away from the machine frame.
17. Remove the cotter pin and clevis pin from
the end of the vacuum head lift cable.
18. Loosen the two larger lift cable jam nuts on
the cable.
19. Pull the cable out of the mount slot. Remove
the lift cable from the machine.
NOTE: Note how the cable was routed in the
machine.
20. Position the new cable into the machine.
The end of the cable with the clevis goes to
the front of the machine. Make sure the new
cable is routed the same manner as the old
one.
21. Install the upper end of the lift cable into the
mount slot on the cable assembly mount
plate. Center the jam nuts on the threads
and tighten tight. Install the clevis and cotter
pin.
22. Position the cable assembly mount plate
back against the front of the machine frame.
Reinstall the three hex screws and tighten to
18 -- 24 Nm (15 -- 20 ft. lb).
23. Reinstall the slide assembly and tighten the
three hex screws to 18 -- 24 Nm
(15 -- 20 ft. lb).
24. Reinstall the propel pedal, clevis pin, and
cotter pin.