Chapter five Keyboard Operation and Usage
5.1 Keyboard layout and function specification
AC60 series frequency inverter has two kinds of keyboards: the single display
type for machine below 011G/015P and the double display type for machine above
015G/018P.
5.1.1 Single display keyboard layout and function specification
Key
Key name
Enter menu while standby or running.Press this key to return
Menu key
while modify parameter. While standby or running, press for
1 sec to enter monitorning interface.
Press to modify parameter while in menu interface.Press again
Confirm/modify
to confirm aftr modify. While standby or running, press to
key
change LED monitoring items at stop
Select parameter group in menu interface. Modify parameter
while in modify interface. Modify given frequency or PID or
Up/down key
given torque while at standby or monitoring state(While
given frequency or PID or given torque are set by keyboard)
Select digit of function no modified by up/down key;Select
Shift key
parameter digits modified by up/dowm key. Change LED
monitoring items while standby or running
34
Key functions