E-19
Reserve
E-20
Carrier frequency
Carrier
E-21
Characteristics
Slip
frequency
E-22
compensation
Energy-saving
E-23
running options
Voltage
auto-adjustment
E-24
function
E-25
Jog frequency
Jog
acceleration
E-26
time
Jog
deceleration
E-27
time
E-28
Start-up frequency
Start-up frequency
E-29
duration
E-30
Start-up options
0.7KHz~15.0KHz
LED single digit: Carrier
frequency associated with
the output setting
0 : Output
frequency
correlation invalid
1 : Input
Frequency
correlation valid
LED "10" digit: Carrier
temperature
correlative
setting
0 : Module temperature
Correlation invalid
1 : Module temperature
Correlation valid
LED "100" digit: PWM
mode options
0:Fixed PWM
1:Random PWM
LED 1000 digit:reserved
0~200%
0:Invalid
1:Valid
0:Invalid
1:Global valid
2:Only
deceleration
invalid
0.00Hz ~ upper
limit
frequency
0.1~6500.0 second
0.1~6500.0 second
0.00~60.00Hz
0.0~20.0 second
0 : Start by start-up
frequency
1: Firstly DC braking,then
start by the start-up
46
113H
78
114H
0000
79
115H
0
80
116H
0
81
117H
0
81
118H
5.00
81
119H
2.0
81
11AH
2.0
81
11BH
0.50
82
11CH
0.0
82
11DH
0
83
11EH