Veichi Electric AC60 series Manual page 118

Table of Contents

Advertisement

Settin
Definition
g value
Relay output terminal
F-30
(TA、TB、TC)
F-31
Output terminal Y1
F-32
Output terminal Y2
Zero
frequency
0
(standby state)
Fault jump
1
alarm 1
Fault jump
2
alarm 2
Frequency
arriving
3
detection
Frequency
4
detection
Function description
Range :0 ~ 19
Range :0 ~ 19
Range :0 ~ 19
When the frequency inverter is running, and the
output is 0.0Hz, it outputs signal.
When there is frequency fault(OU、OL、SC、
OC、LU2、OH etc.) ,including auto-restore
period, it outputs signal
When there is frequency fault(OU、OL、SC、
OC、LU2、OH etc.) ,not including auto-restore
period, it outputs signal
When the output frequency of frequency
inverter reaches or gets close to a certain
range of the given frequency ( this range
determined by the parameter [ F-33] ) , the output
signal is valid, otherwise output signal is
invalid.
When the output frequency of frequency
level
inverter is over the frequency detection
level, it outputs valid signal after [F-35]
delay
time
114
Factory
setting :1
Factory
setting :3
Factory setting :
7
setting.
When
the
output