Separately define control terminal(X1-X6)functions. Short connect with
the terminal(COM)is valid.
Definition
0
Invalid(can reelection)
1
Forward jog operation
2
Reverse jog operation
3
Free stop
4
Fault reset
5
Multi steps speed control 1
6
Multi steps speed control 2
7
Multi steps speed control 3
8
Multi steps speed control 4
Ascend/descend
9
frequency ascending UP
Ascend/descend
10
frequency descending DW
Trilinear
11
control
12
PID control cancel
This port unused
Jog order input port. Terminal jog
orders have the highest priority
Free stop order input port
When breakdown, exterior reset order
input port
The multi steps speed commands input
port. The code combination realizes 15
steps of speed; The multi steps speed
commands has priority only next to the
jog command;
running
Realize the ascend 、descend control
function, invalid when [ E-02] or [ E-03]
running
is set as"7" ;
Trilinear
operational
defined as "D(X)terminal,please
Refer to[F-08] ;
Cancel PID operation when it is PID
control operation;then the PID given
signal is given frequency, frequency
106
Function description
operation
control
is