parameter [H-35 ~ H-49]; Running time is set up by parameter [H-50 ~ H-64];
The time unit is minute; The others are identical with mode "1".
H-33
Program run breakpoint restore
mode selection
0: Running at the first step speed
1: Continue to run as the breakpoint operation frequency and time again.
2: Continue to run as the breakpoint operation frequency for the residual time.
This parameter defines the operation mode of restart after braking off in
running process because of various cause (closing down, malfunction, power
failure etc.).
If selects the "0" mode, the frequency inverter will begin again at the
first step speed.
If selects the "1" mode, frequency inverter will continue to run as the
breakpoint operation frequency and time again.
If selects the "2" mode, frequency inverter will continue to run as the
breakpoint operation frequency for the residual time.
H-34
In run state, power down memory
selection
0:Power down without save
1:Power down with save
This parameter is defined as: when the program operation is selected, whether
to save the program running state while power down (running step no, step
remaining time, acceleration\deceleration time and running direction and so
on). If the power down with save mode is selected, in coordination with the
parameter [H-33], it can define the recover mode of program run after electrify
Range :0,1,2
Range:0,1
143