1. V/F curve setup or
torque boost is not
suitable
2. Network voltage is
relatively low;
3. Machine overload
protection parameter
Machine
is set improperly;
o.L.1
overload
4.Machine block rotor
operation or heavy
load;
5.Universal
low speed with heavy
load
long time;
1.Heavy load ;
2.Acc time is set too
short;
3.
Frequency
machine in running
o.L.2
inverter
when momentary stop
over load
occurs.;
4. V/F curve setup or
torque boost is not
suitable
1. Reset V/F curve or torque
boost value;
2.Check the input power;
3.Check[E-57] setting;
4.Adjust load or select and use
frequency
matching capacity grade;
5. When requiring long term low
speed work, please use special
machine
motor for frequency inverter;
works for a
1. Select frequency inverter
with proper capacity;
Restart
the
2. Lengthen acceleration time;
3.
Restart
completely stop or set[E-30]
as"2" ;
4. Reset V/F curve or torque
boost value;