8:Normal PID operation
normal PID closed-loop control system. The parameter[H-16] can be modified
by Up-down key.
9: Constant pressure PID control
constant pressure PID control ( constant pressure supply water etc. )
closed-loop control system.The parameter[H-16] can be modified by Up-down
key.
10:Program run
The given frequency of the main channel and the running
direction of the frequency inverter is controlled by the process of simple
PLC which inside the frequency inverter, maximum process control is 15 steps
speed; Details sees parameters [E-13, E-14, F-09 ~ F-29, H-32 ~ H-64].
Program running command as start or stop is decided by the given value
of the running order given channel.
When one step speed running time is set as "0", the running program
will skip over this step. It is easy to set up all steps speed of program
run.
When the parameter [E-46] is set as "2" forbid reverse; if running
direction is set as reverse in a step speed, then the frequency inverter works
If you select this channel, it can constitute
If select this channel, it can constitute
67