Chapter seven Function Detailed Specification

7.1 Basic parameters detailed specification

Execute
commands
E-01
channel selection
Select channels which are used to accept operation and stop orders and the
running direction. When restore factory setting,the setting values can
not be changed.
0:Keyboard control
inverter is control by the rotating run keys FWD , reverse operation or
jog keys REV / JOG and parking key STOP / RESET above the Keyboard. REV
/ JOG key parameters is defined as reversion when the [E-08] set to "0",
is defined as jog when the parameters [E-08] set to "1", see [E-08].
1:Terminal control
inverter is control by whether connect the control terminal: Forward
Rotating (FWD)or reverse(REV) to (COM)or not.
2:RS485 Communication
inverter is control by the signal which receive by the RS485
communication port.
Attention: When the fault reset, the STOP / RESET button above the keyboard,
control terminal reset order 、RS485 communication port are effective
reset orders.
Tips:1、When program control, (VS2) input bipolar adjustment, and direction
controlare valid([F-48] setting is 1),the operation direction of the
frequency inverter can not be control by this orders channel.
2、The STOP / RESET key above the keyboard is function selectable. Under
exterior terminal control or communication control, it can be defined
as urgent stop key, please reference the parameters [F-07]; Under
exterior terminal operation control, if use STOP / RESET to stop, the
given
Range :0~2
The operation,stop and direction of the frequency
The operation, stop and direction of the frequency
The operation,stop and direction of the frequency