Continuous Cycle; Signal Cycle, Continuous Running; Signal Cycle - Veichi Electric AC60 series Manual

Table of Contents

Advertisement

time are selected by parameter [H-35 ~ H-49]; Run time is set up by parameter
[H-50 ~ H-64];
The time unit is second.While the first step time up, it shifts to the next
step speed. The time、direction、acceleration\deceleration time of each step
speed can be set; While finishing the 15th section speed running, frequency
inverter will output "0" frequency. If running time of one step is zero, it
will skip over the step during running.
1: continuous cycle (time by second)
After the frequency inverter finishing 15th section speed running, return
to the 1st step speed to begin to work for uninterrupted cycles. Running
direction and acceleration\deceleration time are selected by the parameter
[H-35 ~ H-49]; Run time is set up by parameter [H-50 ~ H-64], the time unit
is second.
2: signal cycle, continuous running (time by second)
After finishing a single cycle running, the frequency inverter does not
close down. It works on at the final step speed whose running time is not zero.
Running direction and acceleration\deceleration time are selected by the
parameter [H-35 ~ H-49]; Run time is set up by parameter [H-50 ~ H-64], the
time unit is second.
3. signal cycle (time by minute)
Direction and acceleration\deceleration time are selected by parameter
[H-35 ~ H-49]; Running time is set up by parameter [H-50 ~ H-64]; The time
unit is minute. The others are identical with mode "0".
4: continuous cycle (time by minute)
Running direction and acceleration\deceleration time are selected by the
parameter [H-35 ~ H-49]; Running time is set up by parameter [H-50 ~ H-64];
The time unit is minute; The others are identical with mode "1".
5: Signal cycle, continuous running (time by minute)
Running direction and acceleration\deceleration time are selected by the
142