Function (Operation / Inspection Mode) - Canon MF735C Series Service Manual

Hide thumbs Also See for MF735C Series:
Table of Contents

Advertisement

COPIER (Service mode for copier) > ADJUST (Adjustment mode) > SCNR
MAI-S-C2
MAI-S-K2

FUNCTION (Operation / inspection mode)

■ INSTALL
COPIER (Service mode for copier) > FUNCTION (Operation / inspection mode) > INSTALL
STRD-POS
Detail
Use Case
Adj/Set/Operate Method
Caution
Required Time
Related Service Mode
CARD-NUM
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Related Service Mode
CARD
Detail
Use Case
Adj/Set/Operate Method
Related Service Mode
ERDS
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Related Service Mode
Supplement/Memo
Not use
Not use
Auto adj of read position at stream read
To automatically adjust the Scanner Unit position in feed direction when stream reading original
with DADF.
The adjustment result is reflected to COPIER> ADJUST> ADJ-XY> STRD-POS.
- At DADF installation/uninstallation
- When replacing the Scanner Unit/clearing RAM data
1) Close the DADF.
2) Select the item, and then press Yes key.
The operation automatically stops after the adjustment.
3) Write the value displayed by COPIER> ADJUST> ADJ-XY> STRD-POS in the service label.
Write the adjusted value in the service label.
10 sec
COPIER> ADJUST> ADJ-XY> STRD-POS
Card first number setting
To set the card first number to be used for Copy Card Reader.
At installation of the Card Reader
Enter the setting value, and then press Apply key.
1 to 2701
1
COPIER> FUNCTION> INSTALL> CARD
Set of Copy Card Reader management info
To set the following management information at installation of the Card Reader.
- Register numbers of 300 cards from the number set in CARD-NUM to the department ID.
- Initialize ID and password of the system administrator.
At installation of the Card Reader
1) Select the item, and then press Yes key.
2) Turn OFF/ON the main power switch.
COPIER> FUNCTION> INSTALL> CARD-NUM
ON/OFF of Embedded-RDS
To set whether to use the Embedded-RDS function.
When using Embedded-RDS
1) Enter the setting value, and then press Apply key.
2) Turn OFF/ON the main power switch.
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
0 to 1
0: OFF
1: ON
It differs according to the location.
COPIER> FUNCTION> INSTALL> RGW-PORT, COM-TEST, COM-RSLT, COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to UGW via SOAP protocol
UGW (Universal Gate Way): Remote monitoring service system
285