ADJUST (Adjustment mode)

■ ADJ-XY
COPIER (Service mode for copier) > ADJUST (Adjustment mode) > ADJ-XY
ADJ-X
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
ADJ-Y
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
ADJ-Y-DF
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Adj start pstn in book mode: vert scan
To adjust the image reading start position (image leading edge position) in the vertical scanning
direction at copyboard reading.
When replacing the Main Controller PCB, enter the value of service label.
Decrease the value when the non-image width is larger than the standard value.
Increase the value when out of original area is copied.
As the value is incremented by 1, the image position is moved to the trailing edge side by 0.1 mm.
- When replacing the Reader Unit
- When replacing the Scanner Unit
- When replacing the Main Controller PCB
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
After the setting value is changed, write the changed value in the service label.
-30 to 30
0.1 mm
0
Adj start pstn in book mode: horz scan
To adjust the image reading start position in the horizontal scanning direction at copyboard reading.
When replacing the Main Controller PCB, enter the value of service label.
Decrease the value when the non-image width is larger than the standard value.
Increase the value when out of original area is copied.
As the value is incremented by 1, the image position is moved to the rear side by 0.1 mm.
- When replacing the Reader Unit
- When replacing the Scanner Unit
- When replacing the Main Controller PCB
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
After the setting value is changed, write the changed value in the service label.
-15 to 15
0.1 mm
0
Adj start pstn: stream, horz scan, front
To adjust the front side image reading start position in horizontal scanning direction at stream
reading.
When replacing the Main Controller PCB, enter the value of service label.
As the value is incremented by 1, the image position is moved to the front side by 0.1 mm.
- When replacing the DADF
- When replacing the Scanner Unit
- When replacing the Main Controller PCB
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
After the setting value is changed, write the changed value in the service label.
-15 to 15
0.1 mm
0