Canon MF735C Series Service Manual page 344

Hide thumbs Also See for MF735C Series:
Table of Contents

Advertisement

TESTMODE (Service mode for test print, operation check, etc.) > FAX (FAX test mode) > MODEM
V34G3TX
Detail
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
■ FACULT
TESTMODE (Service mode for test print, operation check, etc.) > FAX (FAX test mode) > FACULT
G34800TX
Detail
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
V.34 G3 signal transmission test
To test whether the specified V.34 G3 signal is transmitted.
By closing or opening the DC circuit in accordance with the setting value, the specific G3 signal
pattern is transmitted at the specified transmission speed and modulation speed by the G3 signal
transmission function (V.34) of the modem.
Check this with the speaker.
A setting value other than 0 is indicated as a 3-digit integer (1st digit: modulation speed, last 2
digits: transmission speed).
A value other than the specified numerical value is invalid.
Enter the setting value, and then press Apply key.
Be sure to set the value back to 0 after the test.
0 to 614
0: OFF
• First digit (Modulation speed/baud rate)
1: 2400 baud
2: 2743 baud
3: 2800 baud
4: 3000 baud
5: 3200 baud
6: 3429 baud
• Last 2 digits (Transmission speed)
01: 2400 bps
02: 4800 bps
03: 7200 bps
04: 9600 bps
05: 12000 bps
06: 14400 bps
07: 16800 bps
08: 19200 bps
09: 21600 bps
10: 24000 bps
11: 26400 bps
12: 28800 bps
13: 31200 bps
14: 33600 bps
0
G3 4800 bps signal transmission test
To test whether the G3 signal is transmitted at 4800 bps.
By closing or opening the DC circuit, the specific G3 signal pattern is transmitted at 4800 bps by
the G3 signal transmission function.
Check this with the speaker.
Enter the setting value, and then press Apply key.
Be sure to set the value back to 0 after the test.
0 to 1
0: OFF
1: ON
0
335
9. Service Mode

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents