Function (Operation / Inspection Mode) - Canon imageCLASS X LBP1238 II Service Manual

Hide thumbs Also See for imageCLASS X LBP1238 II:
Table of Contents

Advertisement

COPIER (Service mode for printer) > ADJUST (Adjustment mode) > VIFADJ
FU-TMP
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
CRG-HV-K
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
LS-PWR-K
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
TR-HV
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value

FUNCTION (Operation / inspection mode)

■ INSTALL
COPIER (Service mode for printer) > FUNCTION (Operation / inspection mode) > INSTALL
ERDS
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Related Service Mode
Supplement/Memo
Adjustment of Fixing Film surface temperature setting value
To adjust the setting value of the surface temperature of the Fixing Film.
When an image failure occurs
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
-2 to 2
0
Adjustment of primary charging bias setting value (Bk)
To adjust the setting value of Bk-color primary charging bias.
When an image failure occurs
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
-5 to 5
0
Adjustment of laser light emission setting value (Bk)
To adjust the laser light emission setting value of Bk-color.
When an image failure occurs
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
-4 to 4
0
Adjustment of transfer bias setting value
To adjust the transfer bias setting value when ATVC control is executed.
When an image failure occurs
Enter the setting value (switch negative/positive by +/- key), and then press Apply key.
-5 to 5
0
ON/OFF of Embedded-RDS
To set whether to use the Embedded-RDS function.
When using Embedded-RDS
1) Enter the setting value, and then press Apply key.
2) Turn OFF/ON the main power switch.
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
0 to 1
0: OFF
1: ON
COPIER > FUNCTION > INSTALL > RGW-PORT, COM-TEST, COM-RSLT, COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
169