Personal injury and material damage
Some motors, especially the 1FL609❑ are heavy. The excessive weight of the motor
should be considered and any necessary assistance required for mounting should be
sought.
Otherwise, the motor can fall down during mounting. This can result in serious personal
injury or material damage.
NOTICE
Damage to the motor
If the liquid enters the motor, the motor may be damaged
During motor installation or operation, make sure that no liquid (water, oil, etc.) can
penetrate into the motor. Besides, when installing the motor horizontally, make sure that the
cable outlet faces downward to protect the motor from ingress of oil or water.
NOTICE
Magnetic interference to the absolute encoder from the magnetic field
To avoid magnetic interference to the absolute encoder, keep the servo motor with an
absolute encoder at least 15 mm away from the devices that produce a magnetic field
stronger than 10 mT.
Note
Using the eyebolts
The 1FL609❑ motor (90 mm shaft height) has two M8 screw holes for screwing in two
eyebolts. Lift the 1FL609❑ motor only at the eyebolts.