Siemens SINAMICS V90 Operating Instructions Manual page 46

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

General information
2.4 Accessories
Filter used on the three phase power network
Rated current (A)
5
12
20
Basic technical data
Filter used on the single phase power network
Rated current (A)
Rated voltage
Line frequency
Product standard
Power loss
Package size (H × W
× D)
Filter used on the three phase power network
Rated current (A)
Rated voltage
Line frequency
Product standard
Power loss
Package size (H × W
× D)
46
W
W1
W2
55
8.5
38
75
8.5
58
60
10
40
18
Single phase 200 VAC to 240 VAC (-15% to +10%)
50/60 Hz (-10% to +10%)
IEC 61800-5-1
< 1.2 W
230 × 95 ×90
5
Three phase 200 VAC to 480 VAC (-15% to +15%)
50/60 Hz (-10% to +10%)
IEC 61800-5-1
< 1 W
543 × 318 × 351
H
H1
H2
170
158
145
170
158
145
250
240
220
12
< 3 W
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003
D
ø1
130
5
140
5
130
5.5
20
Three phase 380 VAC to
480 VAC (-15% to
+15%)
< 8 W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents