General information
2.6 Technical data
2.6.1.2

SINAMICS V90 PN 400 V variant

General technical data
Parameter
Overload capability
Control system
Dynamic brake
Protective functions
Overvoltage criteria
Speed
Speed control range
control
Torque limit
mode
Environ-
Surrounding air
mental
temperature
condi-
tions
Ambient humidi-
ty
Operating environment
54
Description
300%
Servo control
Built-in
Earthing fault protection, output short-circuit protection
age/undervoltage protection
tection
3)
Category III
Internal speed command 1:5000
Set through a parameter
Opera-
0 °C to 45 °C: without power derating
tion
45 °C to 55 °C: with power derating
Storage
-40 °C to +70 °C
Opera-
< 90% (non-condensing)
tion
Storage
90% (non-condensing)
Indoors (without direct sunlight), free from corrosive gas, combustible gas, oil
gas, or dust
, I
t inverter,I
t motor, IGBT overtemperature pro-
2)
2
2
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003
, overvolt-
1)