8.3 Control word definition
8.3.2

STW2 control word (for telegrams 2, 3, 5)

Signal
STW2.0
STW2.1
STW2.2
STW2.3
STW2.4
STW2.5
STW2.6
STW2.7
STW2.8
STW2.9
STW2.10
STW2.11
STW2.12
STW2.13
STW2.14
STW2.15
8.3.3

STW1 control word (for telegrams 102, 105)

Note
When telegram 105 is used, STW1.4, STW1.5, and STW1.6 are disabled.
Note
STW1.10 must be set to 1 to allow PLC to control the drive.
Signal
STW1.0
STW1.1
STW1.2
STW1.3
STW1.4
182
Description
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
1 = Traverse to fixed endstop
Reserved
Reserved
Reserved
Master sign-of-life, bit 0
Master sign-of-life, bit 1
Master sign-of-life, bit 2
Master sign-of-life, bit 3
Description
= ON (pulses can be enabled)
0 = OFF1 (braking with ramp-function generator, then pulse suppression and ready for
switching on)
1 = No OFF2 (enable is possible)
0 = OFF2 (immediate pulse suppression and switching on inhibited)
1 = No OFF3 (enable is possible)
0 = OFF3 (braking with the OFF3 ramp p1135, then pulse suppression and switching
on inhibited)
1 = Enable operation (pulses can be enabled)
0 = Inhibit operation (suppress pulses)
1 = Operating condition (the ramp-function generator can be enabled)
0 = Inhibit ramp-function generator (set the ramp-function generator output to zero)
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003