Parameters
11.2 Parameter list
Par. No.
Name
p29005
Braking resistor capacity
percentage alarm thresh-
old
Description: Alarm triggering threshold for the capacity of the internal braking resistor.
Alarm number: A52901
p29006
Line supply voltage
Description: Nominal Line supply voltage, effective value of line to line voltage. Drive can operate within -15%
to +10% error.
For 400 V variant servo drive, the value range is 380 V to 480 V, default value is 400 V.
For 200 V variant servo drive, the value range is 200 V to 240 V, default value is 230 V.
p29020[0..
Tuning: Dynamic factor
.1]
Description: The dynamic factor of auto tuning. 35 dynamic factors in total are available.
Index:
[0]: Dynamic factor for one-button auto tuning
[1]: Dynamic factor for real-time auto tuning
p29021
Tuning: Mode selection
Description: Selection of a tuning mode.
0: Disabled
1: One-button auto tuning
3: Real-time auto tuning
5: Disable with default controller parameters
p29022
Tuning: Ratio of total
inertia moment to motor
inertia moment
Description: Ratio of total inertia moment to servo motor inertia moment.
p29023
Tuning: One-button auto
tuning configuration
Description: One-button auto tuning configuration.
Bit 0: The speed controller gain is determined and set using a noise signal.
Bit 1: Possible required current setpoint filters are determined and set using a noise signal. As a conse-
quence, a higher dynamic performance can be achieved in the speed control loop.
Bit 2: The inertia moment ratio (p29022) can be measured after this function is running. If not set, the iner-
tia moment ratio must be set manually with p29022.
Bit 7: With this bit set, multi-axes are adapted to the dynamic response set in p29028. This is necessary
for interpolating axes. The time in p29028 should be set according to the axis with the lowest dynamic re-
sponse.
254
Min
Max
1
100
200
480
1
35
0
5
1.00
10000.00
-
-
Factory
Unit
Data
Setting
type
100
%
Float
400/230 V
U16
18
-
U16
0
-
I16
1.00
-
Float
0x0007
-
U16
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003
Effective
Can be
changed
IM
T
IM
T
IM
T, U
IM
T
IM
T, U
IM
T