Siemens SINAMICS V90 Operating Instructions Manual page 180

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

PROFINET communication
8.2 I/O data signals
Signal
Description
NIST_A
Speed actual value A (16 bit)
NIST_B
Speed actual value B (32 bit)
G1_STW
Encoder 1 control word
G1_ZSW
Encoder 1 status word
G1_XIST1
Encoder 1 actual position 1
G1_XIST2
Encoder 1 actual position 2
MOMRED
Torque reduction
MELDW
Message word
KPC
Position controller gain factor
XERR
Position deviation
AKTSATZ
Position selected block
MDI_TAR
MDI position
POS
MDI_VELO
MDI velocity
CITY
MDI_ACC
MDI acceleration override
MDI_DEC
MDI deceleration override
XIST_A
Position actual value A
OVERRIDE
Position velocity override
1)
MDI_MODE
Position MDI mode
FAULT_CO
Fault code
DE
WARN_CO
Alarm code
DE
POS_ZSW
Position status word
user
User-defined receive word
(p29150):
0: No function
1: Additional torque
(0x4000 = p2003)
2: Additional speed
(0x4000 = p2000)
user
User-defined send word
(p29151):
0: No function
1: Actual torque (0x4000 =
p2003)
2: Actual absolute current
(0x4000 = p2002)
3: DI status
Make sure that signal OVERRIDE is set to a value from 0 to 32767.
1)
180
Receive word/send word
Send word
Send word
Receive word
Send word
Send word
Send word
Receive word
Send word
Receive word
Receive word
Send word
Receive word
Receive word
Receive word
Receive word
Send word
Receive word
Receive word
Send word
Send word
Send word
Receive word
Send word
Data type
Scaling
I16
4000 hex ≙ p2000
I32
40000000 hex ≙ p2000
U16
-
U16
-
U32
-
U32
-
I16
4000 hex ≙ p2003
U16
-
I32
-
I32
-
U16
-
I32
1 hex ≙ 1 LU
I32
1 hex ≙ 1000 LU/min
I16
4000 hex ≙ 100%
I16
4000 hex ≙ 100%
I32
1 hex ≙ 1 LU
I16
4000 hex ≙ 100%
U16
-
U16
-
U16
-
U16
-
I16
-
I16
-
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents