Siemens SINAMICS V90 Operating Instructions Manual page 262

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Parameters
11.2 Parameter list
Par. No.
Name
r0297
DC link voltage overvoltage threshold
Description: If the DC link voltage exceeds the threshold specified here, the drive unit is tripped due to DC link
overvoltage.
Dependency: Refer to F30002.
r0311
Rated motor speed
Description: Displays the rated motor speed (rating plate).
r0333
Rated motor torque
Description: Displays the rated motor torque.
IEC drive: unit Nm
NEMA drive: unit lbf ft
r0482[0...2
Encoder actual position value Gn_XIST1
]
Description: Displays the encoder actual position value Gn_XIST1.
Index:
[0]: Encoder 1
[1]: Encoder 2
[2]: Reserved
Note:
In this value, the measuring gear is only taken into account when the position tracking is activated.
The update time for the position control (EPOS) corresponds to the position controller clock cycle.
The update time in isochronous operation corresponds to the bus cycle time.
The update time in isochronous operation and with position control (EPOS) corresponds to the position
controller clock cycle.
The update time in non-isochronous operation or without position control (EPOS) comprises the following:
Update time = 4 * least common multiple (LCM) of all current controller clock cycles in the drive group
(infeed + drives). The minimum update time is 1 ms.
Example 1: infeed, servo
Update time = 4 * LCM(250 μs, 125 μs) = 4 * 250 μs = 1 ms
Example 2: infeed, servo, vector
Update time = 4 * LCM(250 μs, 125 μs, 500 μs) = 4 * 500 μs = 2 ms
r0632
Motor temperature model, stator winding temperature
Description: Displays the stator winding temperature of the motor temperature model.
r0722
CU digital inputs status
Description: Displays the status of the digital inputs.
Note:
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
The drive unit displays the value in hex format. You can convert the hex number to the binary number, for
example, FF (hex) = 11111111 (bin).
r0747
CU digital outputs status
Description: Displays the status of digital outputs.
Note:
DI/DO: Bidirectional Digital Input/Output
The drive unit displays the value in hex format. You can convert the hex number to the binary number, for
example, FF (hex) = 11111111 (bin).
262
Unit
Data type
V
U16
rpm
Float
Nm
Float
-
U32
°C
Float
-
U32
-
U32
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003