G1_Stw Encoder 1 Control Word - Siemens SINAMICS V90 Operating Instructions Manual

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Signal
STW2.6
STW2.7
STW2.8
STW2.9
STW2.10
STW2.11
STW2.12
STW2.13
STW2.14
STW2.15
8.3.7

G1_STW encoder 1 control word

Signal
G1_STW.0
G1_STW.1
G1_STW.2
G1_STW.3
G1_STW.4
G1_STW.5
G1_STW.6
G1_STW.7
G1_STW.8
G1_STW.9
G1_STW.10
G1_STW.11
G1_STW.12
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003
Description
Reserved
Reserved
1 = Traverse to fixed endstop
Reserved
Reserved
Reserved
Master sign-of-life, bit 0
Master sign-of-life, bit 1
Master sign-of-life, bit 2
Master sign-of-life, bit 3
Description
Selects the function to be activate (with bit value = 1)
Start/stop/read selected function
Mode of the function to be activated
1 = Flying measurement
0 = Search for reference mark
Reserved
Reserved
Reserved
Reserved
Reserved
PROFINET communication
8.3 Control word definition