2.4 Accessories
Note
The 200 V variant servo drive with rated power of 0.1 kW (FSB) does not have a built-in
resistor.
When the motor works in a fast round-trip process, the voltage of the line supply increases.
The braking resistor starts to work if the voltage reaches the set threshold. The temperature
of the heat sink increases (>100 °C) when the braking resistor is working. If alarms A52901
and A5000 appear at the same time, you need to switch the built-in braking resistor to the
external braking resistor. You can select a standard braking resistor according to the table
below:
Power sup-
ply
1/3-phase,
200 VAC to
240 VAC
3-phase,
200VAC to
240 VAC
3-phase,
380 VAC to
480 VAC
Filter
Siemens recommends you to use a line filter to protect the system from high frequency noise.
The line filter restricts the conductive interference emitted from the SINAMICS V90 PN to the
permissible values. The SINAMICS V90 PN drives with these external line filters have been
tested in accordance with the emission requirements of the Category C2 environment. The
conductive emissions and radiated emissions are in compliance with the Class A
requirements of the EN 55011 standard.
Recommended line filters
Power supply
1-phase,
200 VAC to
240 VAC
44
SINAMICS V90 PN
Resistance (Ω)
Frame size
FSB
(0.1 kW to
0.2 kW)
FSB
(0.4 kW)
FSC
FSD
(1 kW)
FSD
(1.5 kW to
2 kW)
FSAA
FSA
FSB
FSC
SINAMICS V90 PN
Frame size
FSB
FSC
Max. power
(kW)
150
1.09
100
1.64
50
3.28
50
3.28
25
6.56
533
1.2
160
4
70
9.1
27
23.7
Rated current (A)
18
6SL3203-0BB21-8VA0
Operating Instructions, 04/2017, A5E37208830-003
Rated power (W)
20
21
62
62
123
30
100
229
1185
Article number
Degree of protection
SINAMICS V90, SIMOTICS S-1FL6
Max. energy (kJ)
0.8
1.23
2.46
2.46
4.92
2.4
8
18.3
189.6