You can also change the assignment of the digital output signal MBR and assign it to any
DO pin with one of the following parameters:
Parameter
p29330
p29331
Note
Refer to Section "Digital inputs/outputs (DIs/Dos) (Page 99)" for detailed information about
the digital outputs.
Wiring for the 200 V variant servo drive
The following diagrams show the examples when the brake is controlled through the motor
holding brake signal (Brake) of the 200 V variant servo drive.
Example 1:
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003
Range
Factory set-
ting
1 to 14
2 (FAULT)
1 to 14
9 (OLL)
Unit
Description
-
Assignment of digital output 1
-
Assignment of digital output 2
Connecting
4.7 Motor holding brake