Parameters
11.2 Parameter list
Par. No.
Name
r2060[0...1
PROFIdrive: PZD receive double word
8]
Description: Displays the PZD (setpoints) with double word format received from the fieldbus controller.
Dependency: Refer to r2050.
Index:
Index [n] = PZD[n +1] + n + 2
In the formula, n = 0...18.
Notice: A maximum of 4 indices of the "trace" function can be used.
r2063[0...2
PROFIdrive: Diagnostics PZD send double word
6]
Description: Displays the PZD (actual values) with double word format send to the fieldbus controller.
Index:
Index [n] = PZD[n +1] + n + 2
In the formula, n = 0...26.
Bit field:
For each PZD, it has 32 bits from bit 0 to bit 31. For the control words, if the bit value equals to 0, the function
of the bit is OFF; if the bit vaule equals to 1, the function of the bit is ON.
Notice: A maximum of 4 indices of the "trace" function can be used.
r2090.0...1
PROFIdrive: PZD1 receive bit-serial
5
Description: Bit-serial description of PZD1 (normally control word 1) received from the PROFIdrive controller.
If the value of the bit equals to 0, it means the function of this bit is deactivated. If the value of the bit equals to
1, it means the function of this bit is activated.
r2091
PROFIdrive: PZD2 receive bit-serial
Description: Binector output for bit-serial interconnection of PZD2 received from the PROFIdrive controller.
r2092
PROFIdrive: PZD3 receive bit-serial
Description: Binector output for bit-serial interconnection of PZD3 received from the PROFIdrive controller.
r2093.0...1
PROFIdrive: PZD4 receive bit-serial
5
Description: Bit-serial description of PZD4 (normally control word 2) received from the PROFIdrive controller.
If the value of the bit equals to 0, it means the function of this bit is deactivated. If the value of the bit equals to
1, it means the function of this bit is activated.
r2094
PROFIdrive: MDI_MOD receive bit-serial for telegram 9
Description: Binector output for bit-serial onward interconnection of a PZD word received from the PROFIdrive
controller.
r2122[0...6
Alarm code
3]
Description: Displays the number of faults that have occurred.
Dependency: Refer to r2124
Note: The buffer parameters are cyclically updated in the background.
Alarm buffer structure (general principle):
r2122[0], r2124[0] → alarm 1 (the oldest)
...
r2122[7], r2124[7] → alarm 8 (the latest)
When the alarm buffer is full, the alarms that have gone are entered into the alarm history:
r2122[8], r2124[8] → alarm 1 (the latest)
...
r2122[63], r2124[63] → alarm 1 (the oldest)
266
Unit
Data type
-
I32
-
U32
-
U16
-
U16
-
U16
-
U16
-
U16
-
U16
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003