Commissioning

5.1

General commissioning information

Prior to commissioning, read "Basic operator panel (BOP) (Page 129)" for more information
about the BOP operations. In case of any faults or alarms during commissioning, refer to
Chapter "Diagnostics (Page 269)" for detailed description.
Carefully read the safety instructions
Before your commissioning or operation, read the safety instructions in Chapter
"Fundamental safety instructions (Page 11)" carefully. Failure to observe the instructions
may cause serious effects.
Material damages and personal injuries by the drop of a hanging axis
When the servo system is used as a hanging axis, the axis will drop if the positive and
negative poles of the 24 V power supply are connected inversely. Unexpected drop of the
hanging axis may cause material damages and personal injuries.
Before commissioning, a crosstie must be used to hold the hanging axis in prevention of an
unexpected drop. In addition, make sure that the 24 V power supply is correctly connected.
NOTICE
Firmware damage due to drive power-off during data transfer
Switching off the 24 V power supply for the drive during data transfer from the micro SD
card/SD card to the drive can cause damage to the drive firmware.
• Do not switch off the drive power supply when the data transfer from the micro SD
NOTICE
Existing setting data may be overwritten by the setting data on the micro SD card/SD card
during startup.
• When a drive is switched on with a micro SD card/SD card containing user setting data,
• When a drive is switched on with a micro SD card/SD card containing no user setting
Before starting up the drive with a micro SD card/SD card, check whether the micro SD
card/SD card contains user setting data. Otherwise, the existing data on the drive may be
overwritten.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003
CAUTION
WARNING
card/SD card to the drive is in process.
the existing setting data on the drive will be overwritten.
data, the drive will automatically save the existing user setting data onto the micro SD
card/SD card.