Siemens SINAMICS V90 Operating Instructions Manual page 253

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Par. No.
Name
p8922[0...
PROFIdrive: Default
3]
gateway of station
Description: Sets the default gateway for the onboard PROFINET interface on the Control Unit.
The active default gateway is displayed in r8932.
Note: The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8923[0...
PROFIdrive: Subnet
3]
mask of station
Description: Sets the subnet mask for the onboard PROFINET interface on the Control Unit.
The active subnet mask is displayed in r8933.
Note: The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8925
PROFIdrive: Interface
configuration
Description: Setting to activate the interface configuration for the onboard PROFINET interface on the Control
Unit.
p8925 is automatically set to 0 at the end of the operation.
p8925 = 0: No function
p8925 = 2: Save and activate configuration
The interface configuration (p8920 and following) is saved and activated after the next POWER ON.
p29000 *
Motor ID
Description: Motor type number is printed on the motor rating plate as motor ID.
For a motor with an incremental encoder, users need to manually input the parameter value.
For a motor with an absolute encoder, the drive automatically reads the parameter value.
p29001
Reversal of motor direc-
tion
Description: Reversal of motor running direction. By default, CW is the positive direction while CCW the nega-
tive direction. After changing of p29001, reference point will lost, A7461 will remind user to referencing again.
0: No reversal
1: Reverse
p29002
BOP display selection
Description: Selection of BOP operating display.
0: Actual speed (default)
1: DC voltage
2: Actual torque
3: Actual position
4: Position following error
p29003
Control mode
Description: Selection of control mode.
1: Basic positioner control mode (EPOS)
2: Speed control mode (S)
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2017, A5E37208830-003
Min
Max
0
255
0
255
0
3
0
65535
0
1
0
4
1
2
Factory
Unit
Data
Setting
type
0
-
U8
0
-
U8
0
-
U8
0
-
U16
0
-
I16
0
-
I16
2
-
I16
Parameters
11.2 Parameter list
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T
IM
T
IM
T, U
IM
T