Table 3-2: Modem status, customization, and reset commands (Continued)
Command
!PCINFO
(Continued)
!PCOFFEN?
!PCOFFEN=<state>
Supporting Mini Cards:
All
!PCTEMPLIMITS?
!PCTEMPLIMITS=<hc>,
<hw>,<hn>,<ln>,<lc>
Supporting Mini Cards:
All
Rev 2.9 Oct.08
Modem Status, Customization, and Reset Commands
Return power control status information (Continued)
(FW rev D0_0_4_2ap and later)
<pwroff> (Current power off mode—preset by device manufacturer):
0 = Enter LPM when W_DISABLE is asserted
1 = Power down modem when W_DISABLE is asserted
2 = Ignore changes on W_DISABLE
<userlpm> (State of user-initiated low power mode)
0 = Disabled (normal power mode)
1 = Enabled (low power mode)
Query / set Power Off Enable state
The modem supports the use of W_DISABLE to cause it to power off.
This command is used to indicate the current state of the Power Off
Enable feature, and to set the state of the feature.
Usage:
AT!PCOFFEN? reports the current <state>.
AT!PCOFFEN=<state> sets the current state.
Parameters:
<state>:
0 = Disabled – The modem will enter LPM (low power mode) when
W_DISABLE is asserted.
1 = Enabled (Default) – The modem will power off when W_DISABLE
is asserted.
2 = Ignore changes on W_DISABLE (FW rev D0_0_4_2 and later).
Query / set temperature state limit values
Certain modem functionality is affected by the modem's temperature state.
The possible temperature states are high critical, high warning, high
normal, low normal, and low critical.
This command is used to report or set the limits that correspond to these
temperature states.
Usage:
AT!PCTEMPLIMITS? returns the temperature limits for each state
(<hc>, <hw>, <hn>, <ln>, <lc>).
AT!PCTEMPLIMITS=<hc>,<hw>,<hn>,<ln>,<lc> sets the temperature
limits for each state (all five values must be specified).
Parameters:
<hc> = High Critical (factory default = 108
<hw> = High Warning (factory default = 95
<hn> = High Normal (factory default = 85
<ln> = Low Normal (factory default = -15
<lc> = Low Critical (factory default = -25
Description
°
C)
°
C)
°
C)
°
C)
°
C)