Cappendix C: Foundation ™ Fieldbus Block Information; Resource Block - Emerson Rosemount 2230 Reference Manual

Graphical field display
Hide thumbs Also See for Rosemount 2230:
Table of Contents

Advertisement

Reference Manual
00809-0100-2230, Rev CA
Appendix C
Resource block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 123
Register transducer block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 128
Main transducer block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 130
Display transducer block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 133
Multiple analog output block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 136
Supported units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 138
C.1

Resource block

This section contains information on the Resource Block of the Rosemount
Display.
The resource block defines the physical resources of the device. The resource block also handles
functionality that is common across multiple blocks. The block has no linkable inputs or outputs.
Table C-1. Resource Block Parameters
Index
Number
01
ST_REV
02
TAG_DESC
03
STRATEGY
04
ALERT_KEY
05
MODE_BLK
06
BLOCK_ERR
07
RS_STATE
08
TEST_RW
09
DD_RESOURCE
10
MANUFAC_ID
11
DEV_TYPE
12
DEV_REV
F
Fieldbus Block Information
OUNDATION
F
OUNDATION
Information
Parameter
Description
The revision level of the static data associated with the function block.
The user description of the intended application of the block.
The strategy field can be used to identify grouping of blocks.
The identification number of the plant unit.
The actual, target, permitted, and normal modes of the block:
Target: The mode to "go to"
Actual: The mode the "block is currently in"
Permitted: Allowed modes that target may take on
Normal: Most common mode for actual
This parameter reflects the error status associated with the hardware or software
components associated with a block. It is a bit string, so that multiple errors may be
shown.
State of the function block application state machine.
Read/write test parameter - used only for conformance testing.
String identifying the tag of the resource which contains the Device Description for
this resource.
Manufacturer identification number – used by an interface device to locate the DD
file for the resource.
Manufacturer's model number associated with the resource - used by interface
devices to locate the DD file for the resource.
Manufacturer revision number associated with the resource - used by an interface
device to locate the DD file for the resource.
F
Fieldbus Block Information
OUNDATION
Fieldbus Block
July 2017
2230S Graphical Field
123

Advertisement

Table of Contents
loading

Table of Contents