Select tanks

In the Select Tanks menu
available:
Default which lets you view all tanks that are configured in the Tank Database of the 2410 Tank Hub
All which displays all available tanks in View Mode
Tank Pos 1-10 which lets you choose the tanks to present in View Mode
Tank position 1-10
The Tank Pos 1-10 menu lets you select which tanks to present in View Mode. Up to ten tanks can be
displayed. Note that the tanks need to be configured in the tank database of the Rosemount 2410 Tank
(2)
Hub
To select tanks:
1. In View Mode, press <Menu> <Options> <Tanks>:
2. Use the up and down arrow softkeys to navigate to the Tank Pos 1-10 menu item.
3. Press the OK softkey to continue to the list of tanks:
4. Use the up and down arrow softkeys to navigate to the desired tank.
5. Press the On/Off softkey to select the tank.
6. When finished, press the OK softkey to return to View Mode.
1.
Not available in Foundation fieldbus systems
2.
See the Rosemount 2410 Tank Hub Reference Manual (Document no. 00809-0100-2410)
Configuration and Operation
(1)
, you can specify which tanks to show in View Mode. The following items are
.
Configuration and Operation