User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX July 2007 Chapter 1 Installation Installation Remove the rubber plug for access to the upper screw of the RDU40 cover. Unscrew and remove all six screws. Remove the cover and take care of the locking device for the weather protection hatch.
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX Chapter 1 Installation July 2007 The RDU40 housing shall be grounded locally to the tank. Use minimum 4 mm or AWG 11 wire. Additional protective ground connection to the power distribution central or the REX junction box is not recommended except where required according to national code of practice.
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX July 2007 Chapter 2 Device Handling Device Handling Before you can start using the RDU40 you must enable it in the REX device, using the REX installation wizard in WinSetup (see TankMaster WinSetup User´s Guide Chapter 3.8.4).
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX Chapter 2 Device Handling July 2007 2.1.1 User defined view To see the most important parameters the user can define an own view where up to six values can be shown, either all at the same time (standard), one by one (toggling) or in Two rows (max three values).
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX July 2007 Chapter 2 Device Handling Setup display for User Defined view Setup can only be made from a master RDU40. See “Two RDU40 connected to the same REX” on page 1-2. Press the Back button until you reach the Main menu and choose Display panel.
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX Chapter 2 Device Handling July 2007 2.3.1 Standard view In the Standard view the items are listed below each other, just as for the Standard view mentioned above, but now the items selected by the user will be shown.
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX July 2007 Chapter 2 Device Handling 2.3.3 Two rows view In the Two rows view the individual status for each value is shown, such as High, HW error and Invalid. Figure 2-5. User defined Two rows view. Now units corresponding to the selected items must be defined.
Page 14
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX Chapter 2 Device Handling July 2007 To edit a holding register, right click on the REX device and choose View Holding Registers. Figure 2-6. View holding registers of the REX device in WinSetup. Write the number of requested holding registers in the Start Register field and press the Read button.
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX July 2007 Chapter 2 Device Handling 2.4.1 User defined view Select items for the User defined view by setting the corresponding bits in holding register 58. Remember the maximum of six items for Toggling or Standard mode and the maximum of three items for Two rows mode: Bit 0 = Level Bit 1 = Ullage...
Page 16
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX Chapter 2 Device Handling July 2007 Length unit in holding register 50: 0 = meters 1 = feet 2 = inches 3 = imperial (1/16) Velocity unit (Level rate) in holding register 51: 0 = Meters per second 1 = Meters per hour 2 = Feet per hour...
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX July 2007 Chapter 2 Device Handling 2.4.2 The single value view From WinSetup it is possible to change the item in the Single value view. The item for the Single value view is selected in holding register 2.4.3 Set timeout for return to default display If the RDU40 is left in Display setup or Service mode it will go back to...
Page 18
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX Chapter 2 Device Handling July 2007 2-10...
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX July 2007 Chapter 3 Troubleshooting Troubleshooting The RDU40 flashes a checkered pattern. Check the following: Bit 0 in holding register 69 set to 1 to enable display control. The part number of the FCC card must be 9150072673b, 9150072675a or later, otherwise the jumpers on the FCC card have to be moved to position 1, according to picture 10.
User’s Guide 308010EN, Edition 2 Rosemount Tank Radar REX Chapter 3 Troubleshooting July 2007 Figure 3-2.RDU40 SW version. If you run the Test LCD a checkered pattern will show but the RDU40 returns to default view in less than a minute. RDU40 LCD problem.
Page 22
User’s Guide 308010EN, Edition 2 July 2007 Rosemount Tank Gauging local representative: Emerson Process Management Rosemount Tank Gauging Box 130 45 SE-402 51 Göteborg SWEDEN Tel (International): +46 31 337 00 00 Fax (International): +46 31 25 30 22 E-mail: sales.srt@emersonprocess.com www.rosemount-tg.com...