QuickPanel Operator User Manual Contents GFK-2847AA Jan 2023 Contents Section 1: Overview ............1 Specifications ....................2 1.1.1 Physical Specifications and Mounting Options ....... 2 1.1.2 Environmental Specifications............. 7 Glossary ......................7 Revisions in this Manual ................8 PACSystems Documentation ................
Page 3
QuickPanel Operator User Manual Contents GFK-2847AA Jan 2023 3.12 VNC Server ..................... 32 3.13 Battery Life Prediction ................. 33 3.14 Simple Network Management Protocol (SNMP) ........37 3.14.1Configure Trap Destinations ............41 3.14.2Enable or Disable SNMP Agent ............42 3.14.3Export MIB to SD Card ..............42 3.14.4Load MIB into SNMP Manager ............
Page 4
QuickPanel Operator User Manual Contents GFK-2847AA Jan 2023 5.7.2 Ethernet for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx .................. 69 5.7.3 Serial Port Details ................70 5.7.4 Universal Serial Bus (USB) Ports ............75 5.7.5 Audio (LINE OUT) Details for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx ................77 5.7.6 Audio (MIC IN) Details (Applicable only to IC755CxS06RDx and IC755CxW07CDx) ................
Page 5
QuickPanel Operator User Manual Contents GFK-2847AA Jan 2023 Appendix A Product Certifications and Installation Guidelines 97 Agency Approvals ..................97 Conditions of Safe Use for Installation in Hazardous Locations ... 98 12CDBCA and 15CDACA ................98 07CDACA ...................... 100 EMC Installation and Operation Considerations ........
Page 6
These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met during installation, operation, and maintenance. The information is supplied for informational purposes only, and Emerson makes no warranty as to the accuracy of the information included herein. Changes, modifications, and/or improvements to equipment and specifications are made periodically and these changes may or may not be reflected herein.
Quick Panel Operator User Manual Section 1 GFK-2847AA Jan 2023 Section 1: Overview Note: This manual specifically describes the QuickPanel IC755CxS06RDx, IC755CxWxxCDx and IC755CxSxxCDx display units. The QuickPanel Operator Interface is an all-in-one micro-computer designed for maximum flexibility. The design is based on an Advanced RISC Machine (ARM) core micro-processor to combine a high-resolution touchscreen operator interface with a variety of communications options.
Quick Panel Operator User Manual Section 1 GFK-2847AA Jan 2023 1.1.2 Environmental Specifications Note: Install the QuickPanel in a well-ventilated location that is not exposed to dust, corrosive gases or liquids, rain, strong ultra-violet light, or direct sunlight, and meets the following specifications. Item IC755CxS06RDx IC755CxW07CDx IC755CxS10CDx IC755CxS12CDx IC755CxS15CDx Cooling...
Added Screensaver - Screensaver is not supported on QP 6" • Inch and 7" Inch. Following Emerson’s acquisition of this product, changes have been made to apply appropriate branding and registration of the Oct 2019 product with required certification agencies. No changes to the material, process, form, fit, or functionality.
Field Agents User Guide GFK-2993 Field Agents Upgrade Guide GFK-3017 In addition to these manuals, datasheets and product update documents describe individual modules and product revisions. The most recent PACSystems documentation is available on the Emerson support website http://www.Emerson.com/Industrial-Automation-Controls. Overview...
Quick Panel Operator User Manual Section 2 GFK-2847AA Jan 2023 Section 2: Hardware This Section describes the QuickPanel hardware features, including physical characteristics and LED indicators. Physical Characteristics In addition to the primary touchscreen interface, the QuickPanel Operator Interface supports a variety of communication ports. The following diagrams illustrate the physical layout of the QuickPanel Operator Interface, including locations of status LEDs, communications ports, and connectors.
Quick Panel Operator User Manual Section 2 GFK-2847AA Jan 2023 Figure 11: Rear View IC755CxS15CDx Note: Refer to the section for drawing dimensions. IC755CxS15CDx Specifications LED Indicators The QuickPanel Operator Interface provides LED indications for the following: Operation status • Ethernet Port operation •...
Quick Panel Operator User Manual Section 2 GFK-2847AA Jan 2023 2.2.2 Ethernet Port Operation LEDs The Ethernet port has two LED indicators: Speed and Link Activity. LED State Operating State Speed Yellow, on 10/100 Link Activity Green, on Link status Hardware...
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Section 3: Software This Section provides QuickPanel software information and procedures to perform the most common tasks. Operating System Note: Refer to http://windows.microsoft.com. The QuickPanel operating system (OS), Microsoft Windows Embedded Compact 7, is a full 32-bit OS with a graphical user interface (GUI).
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Copy Project to SD Card The custom utility Copy Project to SD Card transfers PAC Machine Edition View and Control projects between compatible QuickPanel units using SD cards. CAUTION Before disconnecting power, verify that the copy or update operation is complete (no busy message or wait cursor).
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Note: Depending on set options, the update may or may not be enabled, or may update automatically. If there is more than one flash device with a valid project copy present, a Select Media confirmation window displays, prompting you to choose with which flash device to update Select the device from the list and click OK to continue.
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 an installed SD Card, close your session and log on again to view the SD Card directory. If the SD Card existed when you logged on and is removed and inserted, it will still work, provided the SD Card’s device name did not change during reinsertion.
Page 27
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 DIP Switch 2 (SW2 Switch) controls Force Startup. Turning this • switch to the ON position forces the startup applications to run when the operating system is started. Note: The DIP Switch feature is designed as a security measurement. However, security requirements can also be met using the gesture-based feature.
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 3.9.1 Firmware Upgrade Note: This utility operates similarly to the QuickPanel Update Tool, which comes with the OS image upgrade binaries. The operator can continue to use the QuickPanel Update Tool to use the DIP Switch feature.
Page 29
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 To perform a firmware upgrade 1. From the Start menu, select Programs, System, and QuickPanel OS Utilities Settings Tool to display the QuickPanel OS Utilities Settings window. 2. Upgrade the firmware. Figure 12: Firmware Upgrade Sequence 3.
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Figure 13: Firmware Upgrade Sequence for Specific Firmware Builds NOTICE For a QuickPanel 7” inch Display unit, the following message displays during the process of firmware upgrade. You must re-run the QPPlusUpdate.exe program after reboot, which means you will run the QPPlusUpdate.exe program twice to complete the upgrade process.
Page 31
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Figure 15: Activate Checkbox for Use DIP Switch Figure 16: Enable Bypass Sequence Figure 17: Start-Up Window following Enable Software...
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Figure 18: Start-Up Window following Disable If the Use DIP Switch checkbox has been selected, don’t run Startup Programs displays on the startup window based on the position of DIP Switch 2.
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Figure 19: Sequence to Disable Reset Enhanced Security 3.9.4 Enable or Disable SNMP Agent The QuickPanel Operator Interface can be enabled as a Simple Network Management Protocol (SNMP) Agent with the capability to communicate with SNMP Managers for notification of Traps and responding to Query HMI Tag values.
Page 34
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Figure 20: Sequence to Enable SNMP Figure 21: Acknowledge SNMP Security Risk Notice NOTICE SNMP Communication is enabled on the device only after the user acknowledges this security dialog box (Figure 21) and clicks Yes. Note: Any failure or errors while enabling or disabling the SNMP service would be communicated to the user through a dialog box.
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Figure 22: Sequence to Disable SNMP 3.10 Display Screen Sensitivity Tool The QuickPanel 7”, 10”, 12”, and 15” display units use capacitive screen technology that is far more responsive than the previously used resistive touchscreen technology.
Page 36
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 To modify the Sensitivity Tool 1. From the Start menu, select Programs, System, and Sensitivity Tool to display the Sensitivity Setting window. 2. Set the sensitivity level. Figure 23: Select Screen Sensitivity Level Software...
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 3.11 Launch Application The Launch application window contains the shortcuts to launch some of the major QuickPanel Operator Interface applications. To launch an application Figure 24: Launch Application from Start Menu Figure 25: Select or Browse to Specific Application Software...
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 3.12 VNC Server The VNC Server enables remote, visual connectivity to the QuickPanel Operator Interface from a laptop computer or a mobile device through the remote VNC Viewers. User authentication of the VNC Server in the QuickPanel is determined by the configuration of the Enhanced Security feature on the device.
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 3.13 Battery Life Prediction The QuickPanel Operator Interface provides an estimated lifespan of the battery in the device. To display the battery life prediction, the current time on the QuickPanel device must be set.
Page 40
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 2. After setting the current time, open the QuickPanel Setup Tool, and select the BatteryStatus tab to display the correct battery life prediction information. Figure 29: Example of Battery Life Prediction Displayed After Current Time Set 3.
Page 41
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 5. If the option the battery was replaced is selected, enter the date of when the battery was first used in a QuickPanel device. (This date should reflect the date of first use in any QuickPanel device, not just the current device.) Figure 32: Calendar Entry of Date for Battery was Replaced Option...
Page 42
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 7. Close and re-open the QuickPanel Setup Tool dialog box to display the battery life prediction information. Figure 34: Close and Reopen Message Figure 35: Battery Life Prediction Example after Battery Replacement Software...
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 3.14 Simple Network Management Protocol (SNMP) The SNMP is an application–layer protocol defined by the Internet Architecture Board (IAB) in RFC1157 that is used for exchanging management information between network devices. It is a part of the Transmission Control Protocol/Internet Protocol (TCP/IP) suite.
Page 44
When queried, the return value of each identifier may be different. Figure 37 displays the MIB tree structure and the private enterprise number allocated by the Internet Assigned Numbers Authority (IANA) for the EMERSON SNMP products and OID for the QuickPanel MIB: OID for GEIP node: .1.3.6.1.4.1.24893...
Page 45
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 NOTICE It is highly recommended that you pre-load MIBs (GEIP-SMI.txt and GEIP-PRODUCTS- MIB.txt in sequence) before loading the QuickPanelMIB.mib file into SNMP Managers to avoid any MIB compiler errors. Download the MIBs GEIP-SMI.txt and GEIP-PRODUCTS-MIB.txt from the Support Site.
Page 46
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Note: The list of all HMI tags is populated within the hmiTags node of MIB tree and the HMI Tag access level is currently restricted to Read-only for the SNMP Manager. OID for starting HMI Tag element (also called Index element): .1.3.6.1.4.1.24893.1.5.2.1.1.50.1.1.
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 Section 3.14.6, Establish SNMP Communication • 3.14.1 Configure Trap Destinations TRAP Destinations are configured through the QuickPanel Setup Tool by providing the IP Address of the SNMP Manager to which Traps should be sent.
Management Information Base (MIB) QuickPanelMIB.mib file to an SD Card. NOTICE It is highly recommended that you pre-load Emerson MIBs (GEIP-SMI.txt and GEIP- PRODUCTS-MIB.txt in sequence) before loading the QuickPanelMIB.mib file into SNMP Managers to avoid any MIB compiler errors.
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 A dialog box displays when the copy is successful or if a failure occurs. Figure 42: Success/Failure Annunciation 3.14.4 Load MIB into SNMP Manager After successfully exporting the MIB to an SD Card, archive the QuickPanel MIB file to a folder on a machine running with SNMP Manager.
DISPLAYSTRING data type in the SNMP communication as well. For example, for the Emerson SRTP driver, you can override the IO Address of the LREAL variable LREALVar data type as %R100 [INT]. This maps the LREALVar to DISPLAYSTRING in the MIB file.
Quick Panel Operator User Manual Section 3 GFK-2847AA Jan 2023 3. Enable ab SNMP agent. 4. Export the MIB to an SD Card. 5. Auto-discover or connect the QuickPanel SNMP Agent from the SNMP Manager. Once connected, load the MIB to the SNMP Manager tool.
Care. Before initial power-up, inspect the unit for loose or damaged components. If damage is found (such as bent component leads or loose components), contact Emerson Automation & Controls for additional instructions. CAUTION Do not apply power to the unit if it has visible damage. Applying power to a unit with damaged components may cause additional damage.
Quick Panel Operator User Manual Section 4 GFK-2847AA Jan 2023 Figure 45: IC755CxWxxCDx Example Package Contents Basic Set-up The QuickPanel Operator Interface is shipped ready for use after initial configuration. To power up the unit, connect a dc power supply using the supplied quick-connect plug.
Quick Panel Operator User Manual Section 4 GFK-2847AA Jan 2023 Figure 46: Basic Setup Diagram Initial Start-up You will need the following: Safety Extra Low Voltage (SELV) and Limited Energy Circuit or SELV • and Class 2 dc power supply. The power terminal block is supplied with the product.
Quick Panel Operator User Manual Section 4 GFK-2847AA Jan 2023 5. Apply dc power to the unit. During normal startup and operation, the QuickPanel status LED indicator displays as follows: Solid amber while the QuickPanel is starting up • Solid green during normal operation •...
Quick Panel Operator User Manual Section 4 GFK-2847AA Jan 2023 3. From the Control Panel, double-tap System to configure a Network Device Name. Many applications, including Proficy Historian, require a unique Device Name. NOTICE It is recommended to set a unique Device Name for the QuickPanel+ to avoid future conflicts.
Quick Panel Operator User Manual Section 4 GFK-2847AA Jan 2023 Firmware Updates Update the unit to the most recently released version of the firmware, with the latest feature upgrades and issues addressed. Firmware updates for the QuickPanel are available on the Support website. Default DIP Switch Settings: QP+ Variants QP+ Variants...
Quick Panel Operator User Manual Section 4 GFK-2847AA Jan 2023 Shutdown There are no specific dangers associated with a power failure or other unplanned shutdown of the QuickPanel unit. In general, programs are retained in flash memory and user data can be retained in BBSRAM. Some operating system settings are retained only with user intervention.
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Section 5: Mounting and Installation This Section provides the following procedures to mount and install the QuickPanel Operator Interface: Protective Sheet Installation • Mounting Location • Panel Mounting • VESA Arm Mounting •...
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Mounting Location Note: Refer to Section 1.1.2, Environmental Specifications. When mounting the QuickPanel Operator Interface, make sure the mounting area allows room to insert and remove the SD card, cables, and mounting brackets.
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Panel Mounting To mount the QuickPanel in an enclosure, you will need the following equipment: One #2 Phillips head screwdriver • Mounting brackets (supplied) • The mounting holes for IC755CxS06RDx, IC755CxW07CDx, and IC755CxS10CDx are located on the top and bottom edges of the unit.
Page 62
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Figure 52: Mounting Holes (top & bottom edges) IC755CxS10CDx The IC755CxS12CDx and IC755CxS15CDx mounting holes are located on the top, bottom, and sides of the unit. Figure 53: Mounting Holes (all four edges) IC755CxS12CDx Mounting and Installation...
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Figure 54: Mounting Holes (all four edges) IC755CxS15CDx Mounting and Installation Procedure Observe the following guidelines to properly mount and install the QuickPanel Operator Interface: Note: To order replacement gaskets, refer to the part number listed in Appendix B. The enclosure should be of metal material.
Page 64
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 To install the QuickPanel 1. Cut an opening in the panel according to the specifications in the following figures. Note: Panel cutout tolerances are 0.50, –0.00 mm ( 0.02, –0.00 in). Figure 55: Panel Cutout Dimensions IC755CxS06RDx or IC755CxW07CDx Figure 56: Panel Cutout Dimensions IC755CxS10CDx...
Page 65
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Figure 58: Panel Cutout Dimensions IC755CxS15CDx 2. Verify that the gasket is present and properly seated in the bezel channel located on the sides of the unit. 3. Insert the QuickPanel into the mounting panel cutout.
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 5. Tighten the screws on the mounting bracket in a clockwise direction. Figure 61: Tighten Screws Torque Range for Mounting Clamp Screws Display Unit Torque Range IC755CxS06RDx 0.3 Nm (2.66 in-lb.) IC755CxW07CDx 0.3 Nm (2.66 in-lb.) IC755CxS10CDx...
Page 67
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Figure 62: VESA Mounting Holes IC755CxW07CDx or IC755CxS06RDx Figure 63: VESA Mounting Holes IC755CxSxxCDx Mounting and Installation...
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Battery Installation and Replacement WARNING Batteries may present a risk of fire, explosion, or chemical burn if mistreated. Do not crush, disassemble, short-circuit, or dispose of in fire. Use of batteries not specified for use with the QuickPanel product may present a risk of fire or explosion.
5.6.1 IC755CxS06RDx To install or replace the battery for IC755CxS06RDx: CAUTION Replace the battery for the IC755CxS06RDx only with Emerson battery part number IC755ACCBATT. 1. Remove the battery cover by pressing down while sliding outward. Figure 64: Battery Cover Removal IC755CxS06RDx 2.
Page 70
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 3. Verify that the positive (red) is down and the negative (black) is 4. Wrap the harness connector around to match the following figure. Do not let the harness connector go above the tab. Figure 66: Harness Connector Orientation IC755CxS06RDx 5.
5.6.2 IC755CxW07CDx To install or replace the battery for the IC755CxW07CDx: CAUTION Replace the battery for the IC755CxW07CDx only with Emerson battery part number IC755ACCBATT. 1. Remove the battery cover by pressing down while sliding outward. Figure 67: Battery Cover Removal IC755CxW07CDx 2.
Page 72
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 3. Verify that the positive (red) connection is down and the negative (black) connection is up. 4. Wrap the harness connector around to match the following figure. Do not let the harness connector go above the tab. Figure 69: Harness Connector Orientation IC755CxW07CDx 5.
IC755CxSxxCDx To install or replace the battery for the IC755CxSxxCDx: CAUTION Replace the battery for the IC755CxSxxCDx only with Emerson battery part number IC755ACCBATTNL. 1. Remove the screws (quantity 7) from the back cover. Figure 70: Screw Locations (Back Cover) IC755CxSxxCDx 2.
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 3. Lift and remove the back cover. The battery will be exposed on the back of the unit. Figure 72: Coin Battery Location IC755CxSxxCDx 4. Gently remove the coin battery and replace it with a new one, noting the polarity of the battery.
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 5.7.2 Ethernet for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx The QuickPanel display is equipped with 10Base-T/100Base-TX Ethernet port(s). Connect an Ethernet network cable (unshielded-twisted pair, CAT 5) to the unit through the RJ-45 connector(s) on the bottom of the enclosure.
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 5.7.3 Serial Port Details IC755CxS06RDx Adhere to the following guidelines: A terminal block is supplied with the unit. • The mating terminal block supports stranded 30 to 14 AWG (0.05 to •...
Page 77
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 IC755CxW07CDx Adhere to the following guidelines: A terminal block is supplied with the unit. • The mating terminal block supports stranded 30 to 14 AWG (0.05 to • 2.00 mm2) wires. At a minimum, the cable must be rated for 75°C (167°F), or more.
Page 78
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 IC755CxSxxCDx Note: For an IC755CxS12CDA serial port, refer to Appendix C, Serial Port Details IC755CxS10CDx, IC755CxS12CDA, and IC755CxS15CDx. Adhere to the following guidelines: Terminal blocks are supplied. • The mating terminal blocks support stranded 30 to 14 AWG (0.05 to •...
Page 79
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Serial Port COM2 Details Interface: RS-232C/485 (default is RS-485 Half-duplex) Signal Name Pin-Out RS-485 RS-485 Pin # RS– (Full- (Half- Figure 76: Serial Port COM2 Pin-Out IC755CxSxxCDx 232C duplex duplex) DATA TXD- DATA-...
Page 80
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 DIP Switch Settings COM2 for RS-422 DIPSW ON/OFF DIPSW ON/OFF Figure 77: Example of Full-Duplex (RS–422 Mode) Connection DIP Switch Settings COM2 for RS-485 DIPSW ON/OFF DIPSW ON/OFF Mounting and Installation...
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Figure 78: Example of Half-Duplex (RS–485 Mode) Connection 5.7.4 Universal Serial Bus (USB) Ports USB Host Port Details for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx The QuickPanel has two full-speed USB 2.0 host ports. A variety of third- party USB peripheral devices is also available.
Page 82
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 USB Device Port Details for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx The USB device port allows the QuickPanel Operator Interface to be used as a Slave device. Interface: USB 2.0 Number of Ports: One Connector: Type-B Mini connector Pin # Signal Name...
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 5.7.5 Audio (LINE OUT) Details for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx Interface: LINE OUT (stereo) Number of Ports: One Connectors: Ø3.5 mm jack Maximum output level: 1 Vrms Pin # Signal Name Pin-Out Lineout R Lineout L...
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 5.7.7 SD Card Slot and Storage The QuickPanel is equipped with one standard SD Card port. SD/SDHC memory cards are supported. The SD card slot is spring-loaded for easy insertion and removal. Note: Micro SD slot is not supported on the 6”...
Page 85
Quick Panel Operator User Manual Section 5 GFK-2847AA Jan 2023 Figure 81: SD Card Location IC755CxSxxCDx Mounting and Installation...
QuickPanel Setup tool available in the program system menu. CAUTION Although Emerson recommends the use of the protective sheet, do not operate the touchscreen with any hard materials, such as a screwdriver. This could damage the touchscreen display. Note: IC755CxS06RDx (6”...
Quick Panel Operator User Manual Section 6 GFK-2847AA Jan 2023 6.1.2 Display Backlight Configuration To configure the display backlight 1. Open the QuickPanel Setup Tool and select the Backlight tab to display the Backlight Display Properties window. 2. Set the backlight to automatically turn off in a specific amount of time.
Quick Panel Operator User Manual Section 6 GFK-2847AA Jan 2023 Figure 84: Touchscreen Sensor Calibration Switch 6. Replace the battery cover. Keyboard Configuration The QuickPanel Operator Interface can be configured to use either or both a hardware keyboard and a software emulation keyboard as operator data input devices.
Quick Panel Operator User Manual Section 6 GFK-2847AA Jan 2023 Mouse Any USB-compatible mouse may be used as an input device for the unit. The USB driver for the mouse is included with the operating system and no configuration is required. To use an external mouse, plug it into the appropriate port.
Quick Panel Operator User Manual Section 6 GFK-2847AA Jan 2023 Memory 6.5.1 DRAM Memory The QuickPanel Operator Interface is equipped with Dynamic RAM (DRAM). Part of the DRAM is reserved for the Windows operating system and is not accessible by user applications. The remaining memory is split between two functions: an object store for temporary file storage and the main memory for running programs.
Quick Panel Operator User Manual Section 6 GFK-2847AA Jan 2023 6.5.2 Memory Allocation Modification To change the memory allocation 1. From the Control Panel, double-tap System to display the System Properties window. 2. From the Memory tab, drag the slider bar to divide into Storage and Program memory.
Quick Panel Operator User Manual Section 7 GFK-2847AA Jan 2023 Section 7: Secomea Security (Optional) Secomea Configuration Tool Note: The SiteManager™ and its related GateManager™, LinkManager™, and LinkManager™ Mobile products are licensed, sold, and supported by Secomea and Secomea’s licensed distributors. Additional information is available at www.secomea.com.
Quick Panel Operator User Manual Section 7 GFK-2847AA Jan 2023 Secomea Products Note: Activation and deployment of the Secomea product features are optional. SiteManager, GateManager, and LinkManager products are licensed, sold, and supported by Secomea and Secomea’s licensed distributors. QuickPanel customers wanting to activate licenses for Secomea products can do so at www.secomea.com.
Page 94
Quick Panel Operator User Manual Section 7 GFK-2847AA Jan 2023 Figure 87: Secomea Products used with QuickPanel in Application Secomea Security (Optional)
Quick Panel Operator User Manual Section 8 GFK-2847AA Jan 2023 Section 8: Save and Restore Settings Save and Restore Settings enables the device to store the settings of certain parameters of QuickPanel to a file (the extension assigned to this file type is .qps) and then apply/restore the saved settings to the same QuickPanel or any other QuickPanel...
Page 96
Quick Panel Operator User Manual Section 8 GFK-2847AA Jan 2023 Registry Tab – This tab provides the option to the user to update values to keys in the device registry and save these records to the file so that the stored values can be restored to the corresponding keys, on the same QuickPanel at a later time, or, if needed, also on a different QuickPanel...
Page 97
Quick Panel Operator User Manual Section 8 GFK-2847AA Jan 2023 To update the value to a registry key click on the Add button (Figure 90). This displays a dialog (Figure 91) to enter the values for Key Path, Name, Type, and value. After entering the values click the OK button to close the dialog, and the entered data may be viewed as a record in the Registry tab.
Quick Panel Operator User Manual Section 8 GFK-2847AA Jan 2023 Import Registry Data from XML File An alternate method to input the data to the registry is by using the Import option where the registry value data is available in an XML file and then imported using the Import option in the dialog.
Quick Panel Operator User Manual Section 8 GFK-2847AA Jan 2023 Save the Settings to a File To save the settings and registry values to a file, click on the Save button. This displays the file save dialog, allowing the user to select the folder location and provide the file name.
Quick Panel Operator User Manual Section 8 GFK-2847AA Jan 2023 Restore the Settings from a (.qps) File To restore the settings from a file to a QuickPanel , the following steps need to be executed: 1. Make sure that the file is browsable from the target QuickPanel 2.
Page 101
Quick Panel Operator User Manual Section 8 GFK-2847AA Jan 2023 Figure 98: Browse to and Select .qps File Figure 99: Settings Restored Notification On clicking the Save or Restore button, an Enhanced Security enabled QuickPanel device will prompt the user for the Enhanced Security password.
Page 102
Quick Panel Operator User Manual Section 8 GFK-2847AA Jan 2023 Figure 100: Password Entry Required for Enhanced Security Enabled Save and Restore Settings...
Quick Panel Operator User Manual Appendix A GFK-2847AA Jan 2023 Appendix A Product Certifications and Installation Guidelines The QuickPanel Operator Interface is intended for use in industrial environments and, when properly installed, shall comply with the agency approvals listed in this document. Agency Approvals Note: The agency approvals listed in the following table and on the Declaration of Conformities are...
Quick Panel Operator User Manual Appendix A GFK-2847AA Jan 2023 Conditions of Safe Use for Installation in Hazardous Locations The following information applies to products bearing the UL marking for Hazardous areas and the ATEX marking for Zone 2 explosive atmospheres: Suitable for use in Class I Division 2 Groups A, B, C, D;...
Page 105
Quick Panel Operator User Manual Appendix A GFK-2847AA Jan 2023 2. Insert the retaining clamp in the port above the USB connector. Figure 102: Attach Retaining Clamp 3. Adjust the position of the retaining clamp by pushing the lever on the retaining clamp.
Quick Panel Operator User Manual Appendix A GFK-2847AA Jan 2023 07CDACA The USB retaining clamp for IC755CSW07CDACA must be used in hazardous location installations as follows: 1. Connect the USB retaining clamp plate. Figure 104: Attach USB Retaining Clamp Plate 2.
Page 107
Quick Panel Operator User Manual Appendix A GFK-2847AA Jan 2023 Figure 106: Insert Retaining Clamp into Retaining Clamp Plate WARNING EXPLOSION HAZARD — Do not connect or disconnect equipment power, • communication, audio, or battery unless power has been removed or the area is known to be non-hazardous.
Changes or modifications to this unit that are not expressly approved by Emerson could void the user’s authority to operate the equipment. Industry Canada requires the following note to be published: Note: This Class A digital apparatus complies with Canadian CAN ICES 3 (A)/NMB 3(A).
Orderable Part Numbers QuickPanel Operator Interface Part Numbers Part Number Description QuickPanel 6” Color TFT with Resistive Touch Screen, Emerson Monogram Bezel, 24 Vdc IC755CSS06RDA Powered IC755CBS06RDA QuickPanel 6” Color TFT with Resistive Touch Screen, Blank Bezel, 24 Vdc Powered...
Quick Panel Operator User Manual Appendix C GFK-2847AA Jan 2023 Appendix C Serial Port Details IC755CxS10CDx, IC755CxS12CDA, and IC755CxS15CDx Adhere to the following guidelines: A terminal block is supplied. • The mating terminal block supports stranded 30 to 14 AWG (0.05 to •...
Emerson reserves the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice. Emerson does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson product remains solely with the purchaser.