Device Warnings - Emerson Rosemount 2230 Reference Manual

Graphical field display
Hide thumbs Also See for Rosemount 2230:
Table of Contents

Advertisement

Service and Troubleshooting
July 2017
Message (continued)
numHiddenErrors
numOtherErrors
1.
The register number refers to the internal Input Register of the Rosemount 2230 database.
Note that Input Register data from the Rosemount 2230 display is temporarily stored in the Input Register database of the Rosemount 2410 Tank Hub.
The Input Registers presented in TankMaster WinSetup refer to the internal register area of the Rosemount 2410. Therefore, for tank 1 you will have to add
16000 to the Rosemount 2230 internal register number as given by
Rosemount 2230 display you will have to add 18000 and 20000, respectively.
5.3.5

Device warnings

Device warnings are signaled in the Input Register Device Warnings. Warnings are less serious than errors.
Detailed information about the different warning types can be found in Input registers 1050 - 1070.
Table 5-7. Device warnings
Message
RAM warning
FPROM warning
Hreg warning
Other memory warning
Display warning
Modem warning
Other hardware warning
Measurement warning
ITEMP warning
Software warning
Configuration warning
1.
The register number refers to the internal Input Register of the Rosemount 2230 database. The Input Registers presented in TankMaster WinSetup
refer to the internal register area of the Rosemount 2410 Tank Hub. For tank 1 add 16000 to the Rosemount 2230 internal register number as given
by
Table 5-7
respectively.
94
Description
Input register no. 1132.
Number of hidden errors.
Input register no. 1134.
Number of other errors.
Description
Input register no. 1050
The application software could
not be started.
Bit 0: Stack low
Input register no. 1052
Input register no. 1054.
Bit 0: Default Holding register
values used
Input register no. 1056
Input register no. 1058
Input register no. 1060
Input register no. 1062
Input register no. 1064
Input register no. 1066.
Bit 0: The internal temperature is
out of range
Input register no. 1068.
Bit 1: Stack low (less then 10% left
of stack)
Bit 2: Software startup
Input register no. 1070
Bit 11: Invalid Model Code String
Bit 12: Invalid Model Code
in order to find the register presented by WinSetup. For the second and third 2230 display you will have to add 18000 and 20000,
Action
Contact Emerson Automation Solutions
/Rosemount TankGauging service department.
Table 5-6
in order to find the register presented by WinSetup. For the second and third
Action
(1)
.
Contact Emerson Automation Solutions
/Rosemount TankGauging service department.
Not used
Contact Emerson Automation Solutions
/Rosemount TankGauging service department.
Not used
Not used
Not used
Not used
Not used
Contact Emerson Automation Solutions
/Rosemount TankGauging service department.
Reference Manual
00809-0100-2230, Rev CA
Service and Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents