    PACSystems™ RXi Industrial Displays User Manual Contents GFK-3138E Nov 2022 Contents Section 1: Introduction ............1 An Introduction to RXi – Industrial Displays ............1 Revisions in This Manual ..................1 1.2.1 Advantages to RXi - Industrial Displays ............2 Section 2: RXi - Industrial Monitor Overview ......
  • Page 3 PACSystems™ RXi Industrial Displays User Manual Contents GFK-3138E Nov 2022 3.6.7 Wakeup Configuration ................24 3.6.8 CPU Configuration .................. 25 3.6.9 IDE Configuration ..................26 3.6.10 USB Configuration ................... 27 3.6.11 NCT61120 Super IO Configuration ............28 3.6.12 NCT 6112D HW Monitor................28 3.6.13 NCT 6112D Super IO Features ..............
  • Page 4 PACSystems™ RXi Industrial Displays User Manual Contents GFK-3138E Nov 2022 Primary Technical Features ................60 Display Architecture Options ................60 Configuration and Setup of RXi - Web Panel ............61 4.3.1 Homepage Setup ..................61 4.3.2 System Setup ..................63 4.3.3 Configuration and Setup .................
  • Page 5 PACSystems™ RXi Industrial Displays User Manual Contents GFK-3138E Nov 2022 6.1.2 I/O and Connectors ................113 6.1.3 LED Indicators ..................119 RXi - Panel PC....................120 6.2.1 Battery ....................120 6.2.2 I/O and Connectors ................121 6.2.3 LED Indicators ..................126 RXi - Web Panel ....................
  • Page 6 PACSystems™ RXi Industrial Displays User Manual Contents GFK-3138E Nov 2022 10.2.2 Copying Firmware Files to the Web Panel ..........167 10.3 Updating the Firmware after Copying Firmware Files ........168 10.3.1 Updating Firmware using SSH Client After SSH is Enabled ...... 168 Appendix A: Open-Source Declaration ........
  • Page 7 Changes, modifications, and/or improvements to equipment and specifications are made periodically and these changes may or may not be reflected herein. It is understood that Emerson may make changes, modifications, or improvements to the equipment referenced herein or to the document itself at any time.
  • Page 8: Introduction

    PACSystems™ RXi Industrial Displays User Manual Section 1 GFK-3138E Nov 2022 Section 1: Introduction An Introduction to RXi – Industrial Displays RXi – Industrial Displays are a modular and fanless display portfolio consisting of industrial monitors, web panels, and panel PC options to suit customer visualization and computing needs.
  • Page 9: Advantages To Rxi - Industrial Displays

    PACSystems™ RXi Industrial Displays User Manual Section 1 GFK-3138E Nov 2022 1.2.1 Advantages to RXi - Industrial Displays Scratch Resistance Figure 1: Mohs The RXi – Industrial Displays are robust displays Hardness engineered to resist the harshest environments. The industrial Scale displays feature scratch-resistant glass without the use of plastic overlays and feature screen sensitivity options to adapt...
  • Page 10 PACSystems™ RXi Industrial Displays User Manual Section 1 GFK-3138E Nov 2022 Glove Compatibility RXi Industrial Displays are compatible with a wide variety of PPE, which eliminates the need for a worker to remove gloves to interface with the screens. The figure below illustrates glove compatibility.
  • Page 11: Rxi - Industrial Monitor Overview

    PACSystems™ RXi Industrial Displays User Manual Section 2 GFK-3138E Nov 2022 Section 2: RXi - Industrial Monitor Overview Primary Technical Features HDMI, DP, DP-out (MST-daisy chain), Line-out, USB ports • On-Screen Display (OSD) on the left side • 7”/ 10”/ 12”/ 15”/ 19”/ 24” Widescreen Display •...
  • Page 12: Backing Module And Screen Compatibility

    PACSystems™ RXi Industrial Displays User Manual Section 2 GFK-3138E Nov 2022 Figure 2: Daisy Chaining To enable touchscreen capabilities, the USB cable must be attached from the individual screen back to the IPC. Note: Microsoft Windows limits user input to one touchscreen at a time, even with multiple screens attached to the IPC.
  • Page 13: Configuration And Setup Rxi Industrial Monitor

    PACSystems™ RXi Industrial Displays User Manual Section 2 GFK-3138E Nov 2022 Configuration and Setup RXi Industrial Monitor 2.4.1 On-Screen Display (OSD) AD Board OSD Functions Figure 4: AD Board OSD Functions Legend Auto-Adjust Up/Left Down/Right Power Menu/Entry Power Indicator Power switch: To turn ON or OFF the power Shift the icon to the left side or shift it up Shift the icon to the right side or shift it down Menu: To enter the OSD menu for related icon and item...
  • Page 14: Osd Controls

    PACSystems™ RXi Industrial Displays User Manual Section 2 GFK-3138E Nov 2022 If Unable to Exit Burn-in Mode If the RGB is still on the top left corner of the screen, press to enter Miscellaneous and choose Reset, and then select Yes, and press .
  • Page 15: Main Menu

    PACSystems™ RXi Industrial Displays User Manual Section 2 GFK-3138E Nov 2022 2.5.3 Main Menu Picture To access the main menu, push the Menu button on the OSD controls. Figure 6: Picture Menu Options Menu Items Descriptions AutoBacklight Adjusts the brightness of the screen based on the brightness level of the video in use Backlight Adjusts the brightness of the display...
  • Page 16 PACSystems™ RXi Industrial Displays User Manual Section 2 GFK-3138E Nov 2022 Display Figure 7: Display Menu Options Menu Items Descriptions The screen will calibrate the display to show the best AutoAdjust screen orientation and position H Position Moves the screen left or right (horizontally) V Position Moves the screen up or down (vertically) Disp Rotate...
  • Page 17 PACSystems™ RXi Industrial Displays User Manual Section 2 GFK-3138E Nov 2022 Color Figure 8: Color Menu Options Menu Items Descriptions Panel Uniformity Adjusts color consistency across the screen Gamma Adjusts gamma value Temperature Adjusts temperature value Color Effect Adjusts color effect RXi –...
  • Page 18 PACSystems™ RXi Industrial Displays User Manual Section 2 GFK-3138E Nov 2022 Input Figure 9: Input Menu Options Menu Items Descriptions Auto Select Automatically displays input from whichever ports are supplying media Manually displays input from DisplayPort port HDMI Manually displays input from HDMI port Audio Figure 10: Audio Menu Options Menu Items...
  • Page 19 PACSystems™ RXi Industrial Displays User Manual Section 2 GFK-3138E Nov 2022 Other (Menu Item) Figure 11: Other Menu Options Menu Items Descriptions Reset It will reset the values to original/ default values. Menu Time Adjusts the time that the menu will remain on-screen after pressing the menu button.
  • Page 20: Rxi - Panel Pc Overview

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 Section 3: RXi - Panel PC Overview The RXi - Panel PC is a modular display portfolio that offers multiple options of separable screens and computing units, which maximize flexibility, performance, and durability. The portfolio ranges from 7"...
  • Page 21: Primary Technical Features (Base Model)

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 iPrimary Technical Features (Base Model) 7”/ 10”/ 12”/ 15”/ 19”/ 24” 4x 10/100 base T Ethernet • • Industrial Widescreens RJ45 7”/ 10”/ 12”/ 15” Industrial 1x RS-232, 1x RS-485 •...
  • Page 22: Display Architectural Options

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 Display Architectural Options The RXi – Panel PC can operate as a stand-alone unit or connect directly with an RXi – Industrial Monitor for dual-screen operation. For more information, please see the RXi – Industrial Monitors Data Sheet.
  • Page 23: Drivers Installation

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 Drivers Installation Note: Instructions are the same for Panel PC with or without AMD Ryzen. Read and accept the End User License Agreement (Figure 13). Figure 13: End User License Agreement 3.4.1 Express Installation There are two installation processes.
  • Page 24: Custom Installation

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 Figure 15: Restart Now 3.4.2 Custom Installation Customer installation is available to allow users to specify which drivers they want to install. To proceed: 1. Select Custom Install (Figure 16). 2.
  • Page 25 PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 Figure 17: Drivers Selection Figure 18: Restart Now Note: It is strongly encouraged to restart the Panel PC before continuing. RXi – Panel PC Overview...
  • Page 26: Configuration And Setup With Rxi - Panel Pc

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 Configuration and Setup with RXi – Panel PC 3.5.1 Set Brightness in Panel PC Changing the screen brightness of a Panel PC must be done in the BIOS. 1. During startup, repeatedly press the Delete key. 2.
  • Page 27: Ami Bios Setup Utility (Panel Pc)

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 highlighted field. <F1> Displays general help <F2> Pervious values <F3> Load Optimized Defaults <F4> Saves and resets the setup program. <Esc> Exit to the BIOS Setup Utility. Submenu When “ ” appears on the left of a particular field, it indicates that a submenu that contains additional options are available for that field.
  • Page 28: Advanced

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 BIOS Description Parameter System Choose the system default language. Language The date format is <day>, <month>, <date>, <year>. Day displays a day, System Date from Sunday to Saturday. Month displays the month, from 01 to 12. Date displays the date, from 01 to 31.
  • Page 29: Acpi Settings

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.5 ACPI Settings This section configures system ACPI parameters. Figure 21: ACPI Settings BIOS Parameter Description This field is used to enable or disable BIOS ACPI auto configuration. ACPI Auto Configuration This field is used to enable or disable the system’s ability to hibernate (OS/S4 Sleep State).
  • Page 30: Trusted Computing

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.6 Trusted Computing This section is used to configure the Trusted Computing settings. Figure 22: Trusted Computing BIOS Parameter Description Enable or disable BIOS support for a security device. The Operating System will not show a security device.
  • Page 31: Wakeup Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.7 Wakeup Configuration This section is used to configure the Wakeup ACPI Power Management. Figure 23: Wakeup Configuration BIOS Parameter Description Enable or disable to resume by PME (PCI, PCIe, LAN, Resume by PME etc.) Resume by USB...
  • Page 32: Cpu Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.8 CPU Configuration This section is used to configure the CPU. It will also display the detected CPU information. Figure 24: CPU Configuration BIOS Description Parameter Enable or disable CPU Virtualization. SVM Mode Core Leveling Select the number of cores in the system: Automatic mode, Three cores...
  • Page 33: Ide Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.9 IDE Configuration This section is used to configure the IDE Devices. It will also display the detected information. Figure 25: IDE Configuration RXi – Panel PC Overview...
  • Page 34: Usb Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.10 USB Configuration This section is used to configure the parameters of the USB Device. Figure 26: USB Configuration BIOS Parameter Description Enabled – Enabled Legacy USB Legacy USB Disabled –...
  • Page 35: Nct61120 Super Io Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.11 NCT61120 Super IO Configuration This section is used to configure the parameters of the system super IO chip. BIOS Parameter Description Enable or disable the serial COM port. Serial Port Enable or disable the RS485 auto flow support.
  • Page 36: Nct 6112D Super Io Features

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.13 NCT 6112D Super IO Features This section is used to configure some control functions of the system super IO chip. Figure 28: NCT 6112D Super IO Features BIOS Parameter Description A WatchDog timer (WDT) is a hardware timer that automatically generates a system reset if the main...
  • Page 37: Network Stack Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.14 Network Stack Configuration This section is used to enable or disable network stack settings. The Network Stack Controls LAN1 & LAN2 (Also LAN 3 & LAN4 on large computing module). Figure 29: Network Stack Configuration BIOS Parameter Description...
  • Page 38: Chipset

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.15 Chipset This section configures relevant chipset functions. Figure 30: Chipset Screen BIOS Parameter Description OnChip SATA Channel Enable or disable Serial ATA OnChip SATA Type Select OnChip SATA Type: Native IDE, AHCI, or Legacy IDE. SD Mode Enable or disable Secure Digital (SD) Mode configuration.
  • Page 39 PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 BIOS Parameter Description If the system’s power is on when AC power failure occurs, the system will power-on when power returns. GPP2 Hotplug Mode Enable or Disable GPP2 Hotplug Mode Control Control GPP3 Hotplug Mode Enable or disable GPP3 hotplug mode control.
  • Page 40: Boot Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.16 Boot Configuration Figure 31: Boot Configuration Menu BIOS Parameter Description Select the number of seconds to wait for the setup Setup Prompt Timeout activation key. 65535(0xFFFF) denotes indefinite waiting.
  • Page 41 PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 Hard Drive BBS Priorities Set the order of the legacy devices in this group. Figure 32: Hard Drive BIOS Boot Specification BIOS Parameter Description Launch CSM This field is used to enable or disable to launch of CSM. This option controls what device(s) the system will boot Boot Option Filter This field controls the execution of UEFI and Legacy PXE...
  • Page 42: Security

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.17 Security Figure 33: Security BIOS Parameter Description Administrator Password Set the administrator password. User Password Set the user password. This section is used to configure customizable secure Secure Boot Menu boot settings.
  • Page 43 PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 Key Management This section enables experienced users to modify secure boot variables. Figure 34: Key Management BIOS Description Parameter Enable or disable to install factory default secure boot keys when the Default Key system is in setup mode.
  • Page 44 PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 BIOS Description Parameter Select Yes and press Enter to set a new DBX or select No and press Enter Set new DBX to load it from a file on external media. Select Yes and press Enter to set a new DBT or select No and press Enter Set new DBT to load it from a file on external media.
  • Page 45: Save & Exit

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.6.18 Save & Exit Menu Options Figure 35: Menu Options BIOS Parameter Description To save the changes, select this field and then press Save Changes and Reset Enter. A dialog box will appear. Select Yes to reset the system after saving all changes made.
  • Page 46: Accessing The Bios (Panel Pc With Amd Ryzen)

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 Accessing the BIOS (Panel PC with AMD Ryzen) 3.7.1 Main The Main menu is the first screen that you will see when you enter the BIOS Setup Utility. BIOS Description Parameter Choose the system default language.
  • Page 47: Amd Chipset Settings

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.2 AMD Chipset Settings This section configures AMD CBS parameters. Figure 36: AMD Chipset Setting BIOS Parameter Description Ac Loss Control Select Ac Loss Control Method. DRAM ECC Use this option to enable/disable DRAM ECC. The auto will Enable set ECC to enable.
  • Page 48: Trusted Computing

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.3 Trusted Computing This section is used to configure the Trusted Computing settings Figure 37: Trusted Computing BIOS Description Parameter Security Enable or disable BIOS support for a security device. O.S. will not show a Device security device.
  • Page 49: Pci-E Port Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.4 PCI-E Port Configuration Figure 38: PCI-E Port Configuration BIOS Parameter Description Hotplug Mode To enable/disable Hotplug Mode Control of Mini PCIe. Control(Mini PCIE) Hotplug Mode To enable/disable Hotplug Mode Control of M.2-E. Control (M.2 -E) Dimming Control This section is used to configure displays and dimming.
  • Page 50: Advanced

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.5 Advanced Figure 39: Advanced BIOS Parameter Description Output To enable/disable LCD panel display. Mode Output To enable/disable rear DP display. Mode Auto Backlight To dim backlight by TB573D. Dimming Minimum Dimming...
  • Page 51: Acpi Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.6 ACPI Configuration This section configures system ACPI parameters. Figure 40: ACPI Configuration BIOS Parameter Description Enable/disable integrated LAN to Wake on PCIe wake the system Wake on RTC Resume by RTC Alarm after S5 from S5 shutdown...
  • Page 52: Nct611D Super Io Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.7 NCT611D Super IO Configuration Figure 41: NCT611D BIOS Parameter Description WatchDog Select WatchDog Timer Unit by Timer Unit second or minute. SuperIO Disable the timer by value 0 or set WatchDog another timeout value to enable the Timer...
  • Page 53: Serial Port Console Redirection

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.8 Serial Port Console Redirection Figure 42: Serial Port Console Redirection BIOS Parameter Description Console Enable / disable console direction. Redirection Specify how the host computer and the remote one Console (which the user is using) will exchange data.
  • Page 54: Serial Port Console Redirection

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.9 Serial Port Console Redirection Figure 43: Serial Port Console Redirection BIOS Parameter Description VT100 – ASCII CharSet VT100+ Extends VT100 to Support color and function keys ANSI VT-UTF8 - Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.
  • Page 55 PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 BIOS Parameter Description Even - Parity bit is 0 if the num of 1’s in the data bits is even. A parity bit Odd - Parity bit is 0 if the num of 1’s in can be sent the data bits is odd.
  • Page 56: Cpu Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.10 CPU Configuration This section is used to configure the CPU. Figure 44: CPU Configuration BIOS Parameter Description Enable or disable the generation of ACPI _PPC, _PSS, and PSS Support _PCT objects.
  • Page 57: Usb Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.11 USB Configuration This section is used to configure the parameters of a USB device Figure 45: USB Configuration BIOS Parameter Description Legacy USB Support Enable or disable Legacy USB support. This is a workaround for OSes without XHCI hand-off XHCI Hand-off support.
  • Page 58: Csm Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.12 CSM Configuration Enable or disable CSM options, Option ROM execution settings, etc. Figure 46: CSM Configuration BIOS Parameter Description CSM Support Enable or disable CSM support RXi – Panel PC Overview...
  • Page 59: Network Stack Configuration

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.13 Network Stack Configuration This section is used to enable or disable network stack settings. Figure 47: Network Stack Configuration BIOS Parameter Description Network Stack Enable or disable the UEFI network stack. When Network Stack is set to enabled, the below settings will be shown.
  • Page 60: Security

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.14 Security Figure 48: Security BIOS Parameter Description Administrator Password Set the administrator password Secure Boot Secure boot configuration RXi – Panel PC Overview...
  • Page 61: Secure Boot Menu

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.15 Secure Boot menu This section is used to configure customizable secure boot settings. Figure 49: Secure Boot Menu BIOS Parameter Description Enable or disable secure boot. Secure Boot features are active if Secure Boot is enabled, Platform Key(PK) is enrolled Secure Boot and the System is in User mode.
  • Page 62: Secure Boot Menu

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.16 Secure Boot menu BIOS Parameter Description Factory Key Provision Install factory default Secure Boot Keys after the platform reset and while the System is in Setup mode. Restore Factory Keys Force System to User mode.
  • Page 63: Secure Boot Variables

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.17 Secure Boot Variables Figure 50: Secure Boot Variables Enroll Factory Defaults or load certificates from a file: 1. Public Key Certificate: a) EFI_SIGNATURE_LIST b) EFI_CERT_X509 (DER) c) EFI_CERT_RSA2048 (bin) d) EFI_CERT_SHAXXX 2.
  • Page 64: Boot

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.18 Boot Figure 51: Boot BIOS Parameter Description Setup Prompt Timeout Select the number of seconds to wait for the setup activation key. 65535(0xFFFF) denotes indefinite waiting. This allows you to determine the default state of the numeric keypad.
  • Page 65: Save & Exit

    PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 3.7.19 Save & Exit Figure 52: Save & Exit' BIOS Description Parameter To save the changes, select this field and then press <Enter>. A dialog Save Changes box will appear. Select Yes to reset the system after saving all changes and Reset made.
  • Page 66 PACSystems™ RXi Industrial Displays User Manual Section 3 GFK-3138E Nov 2022 1. Due to safety concerns, the BIOS (SPI ROM) chip cannot be removed from this system board and used on another system board of the same model. 2. The BIOS (SPI ROM) on this system board must be the original equipment from the factory and cannot be used to replace one which has been utilized on other system boards.
  • Page 67: Rxi - Web Panel Overview

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Section 4: RXi - Web Panel Overview An Emerson display that provides the ability to view web-hosted interfaces and dashboards. Primary Technical Features Yocto Linux OS Version 5.15.5 • HTML5 Capability •...
  • Page 68: Configuration And Setup Of Rxi - Web Panel

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Configuration and Setup of RXi - Web Panel 4.3.1 Homepage Setup Once the non-privileged wpuser and privileged wpadmin password are set, the user will need to input the URL/IP address. The URL/IP address will enable the user to complete first-time set- up activities.
  • Page 69 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Figure 54: Homepage Setup RXi – Panel PC Overview...
  • Page 70: System Setup

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 4.3.2 System Setup System Setup page is used to configure the Web Panel settings. Steps to Open Setup Pages 1. Navigate to setup Page either by clicking the Setup button on the Homepage setup page as shown in Figure 55 or on the startup screen as shown in Figure 56 to access the System Setup page.
  • Page 71 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 2. The user needs to provide the non-privileged wpuser and privileged wpadmin credentials and click on the Confirm button to access Web Panel settings. Figure 57: System Setup 3. The user can configure Web Panel settings as shown on the below screen. RXi –...
  • Page 72 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Setup Page When Logged In Using Privileged Wpadmin This is the System Setup page as viewed when logged in as wpadmin. Figure 58: System Setup RXi – Panel PC Overview...
  • Page 73 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Setup Page When Logged In Using Non-privileged wpuser This is the System Setup page as viewed when logged in as Non-Privileged wpuser . Figure 59: System Setup Homepage RXi – Panel PC Overview...
  • Page 74 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 WebPanel Settings Icons Displayed Description File System Build Display the File System Build Date Date Authenticated user Display the Authenticated user Click on Brightness icon to adjust Brightness the Brightness and configure Screen standby interval timer Click on Date and Time icon to set Date and Time...
  • Page 75 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 WebPanel Settings Icons Displayed Description Click on Desktop Restart to close Desktop Restart and start the browser again. Click on System Reboot to reboot System Reboot the complete device. Click on Enable SSH Server button to enable the SSH and click on Enable/Disable SSH...
  • Page 76: Configuration And Setup

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Swipe Gesture To Open Setup Page Swipe your finger from top to bottom in the upper left corner of any screen to open the setup page. The user needs to swipe the finger slowly. Figure 60: Swipe Gesture 4.3.3 Configuration and Setup...
  • Page 77 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 The password must meet the following criterion: Must contain at least 8 characters • Must be fewer than 32 characters • Must be a combination of both upper-case and lower-case letters (case sensitivity) •...
  • Page 78: Adjusting Screen Sensitivity

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 4.3.4 Adjusting Screen Sensitivity TouchTool Steps 1. Navigate to Setup Page and provide the non-privileged wpuser or privileged wpadmin credentials and click on Confirm. Figure 62: System Setup Login 2.
  • Page 79 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 3. Click the Apps button in the upper-left corner of the Chromium browser. Figure 64: Open Apps 4. Select Touch for touchpoint and screen sensitivity adjustment as shown in Figure 65. Figure 65: Touch RXi –...
  • Page 80 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 5. Select how many touchpoints are required. Figure 66: EETI Touch Tool RXi – Panel PC Overview...
  • Page 81 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Set Sensitivity level appropriately based on the touchpoint Figure 67: EETI Touch Tool 6. Click the Apply button. 7. Click the Setup button to go back to main System Setup Page. RXi –...
  • Page 82 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Back to Kiosk Mode Steps to go back to Kiosk mode if the user has exited the Kiosk Mode. 1. Open Apps as shown in below figure: Figure 68: Open Apps 2.
  • Page 83 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 3. Select Desktop Restart as shown below to enter kiosk mode. Figure 70: Desktop Restart RXi – Panel PC Overview...
  • Page 84: Adjusting Screen Brightness

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 4.3.5 Adjusting Screen Brightness 1. Navigate to Setup Page and provide the non-privileged wpuser or privileged wpadmin credentials and click on Confirm. Figure 71: System Setup 2. Select Brightness icon to adjust backlight dimming or ALS on/off control Figure 72: Select Brightness from System Setup RXi –...
  • Page 85 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Note: The RXi Web Panel uses a photodiode to sense the ambient light and in turn, the microcontroller reads the Ambient Light Sensor (ALS), adjusting the LCD backlight. The manual adjustment bar will only be shown when Ambient Light Sensor (ALS) is off. •...
  • Page 86: Energy Saving Mode

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 4.3.6 Energy Saving Mode This is used to turn off the backlight when there is no activity happening on Web panel. 1. Navigate to Setup Page and provide the Non-privileged wpuser or privileged wpadmin credentials and click on Confirm Figure 74: System Setup 2.
  • Page 87: User Password Settings

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Screen standby interval time can be set by incrementing the value between 1 to 30 minutes and clicking the Apply button Figure 76: Energy Saving Mode 3. Click on Setup to go back to main System Setup Page. Note : Energy Saving Mode can be disabled by inputting the value to 0 and clicking the Apply button.
  • Page 88 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 2. Select the password icon (Figure 78). Figure 78: Select the Password Icon from the Setup Page 3. Enter the current (old) and new password and then click the Apply to submit the new password.
  • Page 89: Changing The Password For The Privileged Wpadmin

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 4.3.8 Changing the Password for the Privileged Wpadmin 1. Navigate to Setup Page and provide the privileged wpadmin credentials and click on Confirm. Figure 80: System Setup RXi – Panel PC Overview...
  • Page 90 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 2. Select the password icon (Figure 81). Figure 81: Select the Password Icon RXi – Panel PC Overview...
  • Page 91 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 3. Enter the current (old) and new password then click Apply to submit the new password. Figure 82: Set User Password 4. Click Setup to go back to main System Setup Page. RXi –...
  • Page 92: Network Setup

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Network Setup 4.3.9 1. Navigate to Setup Page and provide the non-privileged wpuser or privileged wpadmin credentials and click on Confirm. Figure 83: System Setup 2. Select the Network Setup icon (Figure 84). Figure 84: Select Network Setup RXi –...
  • Page 93: Date And Time Settings

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 3. Assign values to the Network parameters to setup your network and click Apply. Figure 85: Network Setup Note: Be sure to provide a DNS value, otherwise an error will display when the user clicks Apply.
  • Page 94 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 2. Select Date and Time as shown in Figure 87. Figure 87: Select Date and Time RXi – Panel PC Overview...
  • Page 95 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 3. Manually set the date and time and click Set Date and Time. Input the NTP server IP address and click Apply. Figure 88: Date and Time Setup 4. Click Connect NTP Server button to connect to NTP Server. 5.
  • Page 96: Display Orientation

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 4.3.11 Display Orientation The user can set the following display screen rotations on the RXi Web Panel : rotation. • rotation. • rotation. • rotation. • By default, screen display is set to 0 1.
  • Page 97 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 2. Select 90 , 180 , or 270 as shown in the boxed area of Figure 90. Figure 90: Screen Rotation 3. After clicking the screen orientation icon, the user will be prompted with the following message: Press OK to rotate <degree>...
  • Page 98: Firewall Support

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Firewall Support Firewall Support is included by enabling iptables module. Iptables is a software firewall for Yocto Linux Kernel. Iptables is a command-line interface for configuring and maintaining tables in the Yocto Linux kernel's Netfilter firewall for IPv4.
  • Page 99 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 2. Select terminal as shown in below figure: Figure 92: Select the Terminal icon RXi – Panel PC Overview...
  • Page 100 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Switch to the privileged user wpadmin by running the su wpadmin command and entering the password for the wpadmin user. 3. Run sudo iptables -S Figure 93: Run command iptables -S RXi –...
  • Page 101: Firewall Rules

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 4.4.1 Firewall Rules # Flush all existing rules Iptables # Set 'close all ports' chain policies iptables -P INPUT DROP iptables -P FORWARD DROP iptables -P OUTPUT DROP # apt-get to resolve (53) and initiate connections (80, 443) to fetch updates from repo iptables -A INPUT -p udp --sport 53 -j ACCEPT iptables -A OUTPUT -p udp --dport 53 -j ACCEPT iptables -A INPUT -p tcp --sport 80 -j ACCEPT...
  • Page 102 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 iptables -A INPUT -p icmp --icmp-type echo-reply -j ACCEPT # Accept loopback access iptables -A INPUT -i lo -j ACCEPT iptables -A OUTPUT -o lo -j ACCEPT #Accept NTP Server Ports iptables -A OUTPUT -p udp --dport 123 -j ACCEPT iptables -A INPUT -p udp --sport 123 -j ACCEPT # ANTI DDOS...
  • Page 103: Saving Firewall Rules

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 4.4.2 Saving Firewall Rules 1. Navigate to Setup Page and provide the non-privileged wpuser or privileged wpadmin credentials and click on Confirm. Figure 94: Credentials RXi – Panel PC Overview...
  • Page 104 PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 2. Select terminal as shown below: Figure 95: Terminal 3. Switch to the privileged user wpadmin by running the su wpadmin command and entering the password for the wpadmin user 4.
  • Page 105: Secure Shell (Ssh) Key Pair

    PACSystems™ RXi Industrial Displays User Manual Section 4 GFK-3138E Nov 2022 Secure Shell (SSH) Key Pair SSH allows secure transfer protocols using encryption only. Encryption keys are therefore automatically exchanged between server and client. So, if establishing an SSH client connection for the first time, the user will be asked to accept the remote host public key.
  • Page 106: Specifications

    PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 Section 5: Specifications RXi - Industrial Monitor Size (inch) 7" 10" 12" 15" 19" 24" 1024 x 600 Resolution 1280 x 800 WXGA 1920 x 1080 Full HD WSVGA Widescree Format Widescreen (16:10)
  • Page 107 PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 Size (inch) 7" 10" 12" 15" 19" 24" Humidity Operating 10000 ft. (3.000 m) Altitude 1 Grms / 5 ~ 500Hz (Random) / Operation IEC 60068-2-64 Vibration 10 G peak acceleration (11 msec. duration)/operation IEC 60068-2-27 UL and cUL Information Technology Equipment (UL/CSA 62368-1) UL and cUL Class 1 Division 2: Programmable Controllers for Use in Hazardous Locations (UL/CSA 61010-2-201, UL 121201, CSA C22.2 No.
  • Page 108: Rxi - Industrial Monitor Motherboard Specifications

    PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 5.1.1 RXi - Industrial Monitor Motherboard Specifications Item Description Board Size 170 x 113mm Scalar IC Realtek RTD2556T-CG 1 x HDMI Input Input 1 x Display Port (DP) Input (DP1) 1 x USB 2.0 (Type B) 1 x Support up to 24-bit LVDS FULL HD panel interface Output...
  • Page 109: Rxi - Panel Pc

    PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 RXi - Panel PC 5.2.1 Panel PC (Base Model) Display Size 7" 10" 12" 15" 19" 24" 1024 x 600 Resolution 1280 x 800 WXGA 1920 x 1080 Full HD Format Widescreen (16:10) Widescreen (16:9)
  • Page 110 PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 Display Size 7" 10" 12" 15" 19" 24" Projected Capacitive Touch Technology (PCT/PCAP) Touchscreen Multi-touch Touch Sensor (Ten-Point) 2 x 10/100/1000 4 x 10/100/1000 Base T Ethernet RJ45 Port 1 Base T Ethernet RJ45 Note: Ports will have Note: Ports will have unique IP addresses...
  • Page 111 PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 Display Size 7" 10" 12" 15" 19" 24" Specification 11kg 192(W) 267(W) 329.1(W) 410.2(W) 500(W) 600(W) Dimensions (mm) 137(H) 186.2(H) 226.8(H) 257.6(H) 315(H) 382(H) 65(D) 65(D) 66(D) 65(D) 70(D) 71(D) UL and cUL Information Technology Equipment (UL/CSA 62368-1) UL and cUL Class 1 Division 2: Programmable Controllers for Use in Hazardous Locations...
  • Page 112: Panel Pc Motherboard Specifications

    PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 5.2.2 Panel PC Motherboard Specifications Item Description Board Size 170mm x 113mm AMD® Embedded G-Series AMD® GX-210HL, Dual-Core, 1M Cache, 1.0GHz, 7W CPU Support AMD® GX-412GC, Quad-Core, 2M Cache, 1.2GHz, 15W Onboard 4GB/8GB DDR3L Memory with ECC Memory Support Supports Single Channel DDR3 1066/1333MHz...
  • Page 113: Panel Pc (With Amd Ryzen)

    PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 5.2.3 Panel PC (with AMD Ryzen) Display Size 7" 10" 12” 15" 19" 24" Resolution 1920 x 1080 Full HD Format Widescreen (16:9) Orientation Landscape 176 (H) / 170 (H) / 170 Reading Angle (°) 178 (H) / 178 (V) 176 (V)
  • Page 114 PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 Display Size 7" 10" 12” 15" 19" 24" Power Maximum Wattage 49 W 52 W 50 W 64 W Consumption Front-Side IP66 & Type 4/4X (When Installed to a suitable Wall/Panel) Protection-Class Back-Side IP20...
  • Page 115: Panel Pc Motherboard Specifications (Panel Pc With Amd Ryzen)

    PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 5.2.4 Panel PC Motherboard Specifications (Panel PC with AMD Ryzen) Item Description Board Size 282mm (11.1") x 138mm (5.43") AMD® Embedded V1000-Series SoC CPU Support AMD® V1404I, Quad-Core, 2M L2 Cache, 2.0~3.6GHz, 15W AMD®...
  • Page 116: Rxi - Web Hmi Panel

    PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 RXi - Web HMI Panel Display Size 7" 10" 12" 15" 19" 24" 1024 x 600 1920 x 1080 Resolution 1280 x 800 WXGA WSVGA Full HD Widescreen Widescreen Format (16:10) (16:9)
  • Page 117 PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 Operating Linux kernel 5.15.5: Yocto System Tool 1 Web Browser Software Tools Tool 2 HTML5 Capability Secure and Item 1 CAAM Trusted Boot Housing Aluminum Die Casting (Front) Design Construction Type Modular (Detachable Modules;...
  • Page 118: Rxi - Web Panel Hmi Motherboard Specifications

    PACSystems™ RXi Industrial Displays User Manual Section 5 GFK-3138E Nov 2022 5.3.1 RXi - Web Panel HMI Motherboard Specifications Item Description Board Size 170mm x 113mm, 10 Layers, 1.6mm CPU Support Freescale ARM Cortex A9 i.MX6 Dual Lite 1.0GHz Memory Support Onboard 2GB DDR3L SDRAM Onboard 4GB eMMC Flash Storage...
  • Page 119: Hardware

    PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 Section 6: Hardware RXi - Industrial Monitor 6.1.1 Jumpers and Connectors Location Figure 96: Jumpers and Connectors Location Connecting Input Power (24V DC-in) To connect to power, follow these steps: 1.
  • Page 120: I/O And Connectors

    PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 6.1.2 I/O and Connectors DC_IN1 (3.5mm Pitch 1x3 Pin Connector), DC24V power input connector Pin # Power Input Pin1 DC+24V Pin2 Ground Pin3 HDMI (HDMI Input) (HDMI Connector), High Definition Multimedia Interface connector, provides high-quality video and audio input.
  • Page 121 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 DP1 (Display Port Input) (Display Port Connector), Display Port Interface connector, provide high-quality video and audio input. Signal Name Pin# Pin# Signal Name LANE3- LANE3+ LANE2- LANE2+ LANE1- LANE1+ LANE0- LANE0+ AUX_CHP...
  • Page 122 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 CN2 - Reserved (2.0mm 1x4 Pin Header) Pin # Signal Name HOST_I2C_SCL HOST_I2C_SDA HOST_IRQ_OUT CN3 - Reserved (2.0mm 1x4 Pin wafer connector), Reserved for IR receiver Pin # Signal Name 3.3V CN4 (OSD) (2.0mm 1x9 Pin wafer connector), On-Screen Display menu Control connector.
  • Page 123 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 CN5 (LVDS Output) (2.0mm 2x25 Female Pin Header), Connect to TB-572B, providing LVDS, USB, SM BUS, and LED signals. Signal Name Pin# Pin# Signal Name +12V +12V BackLight Enable BackLight CTRL Panel 3.3V Panel 3.3V...
  • Page 124 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 CN6 (USB 2.0) (2.0mm 1x9 Pin wafer connector), For external USB2.0 signal. Figure 98: USB2.0 Pin # Signal Name USB 5V USB- USB+ CN7 (Line Out) (Diameter 3.5mm Jack), Line Out audio port. Line Out can be connected to headphones, speakers, or an amplifier.
  • Page 125 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 (2.0mm Pitch 1x3 Pin Header), Backlight control setting. JP1 Pin # Function Close 1-2 For PWM Mode (Default) Close 2-3 For DC Mode SW1 - Reserved Panel Type Select. Hardware...
  • Page 126: Led Indicators

    PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 6.1.3 LED Indicators Operation Status LEDs (Screen) All RXi Industrial Displays have a tri-color LED built into the screen that provides a visual indication of the operation status. Figure 100: LED Location (Circled) LED State System State Amber, Solid...
  • Page 127: Rxi - Panel Pc

    PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 RXi - Panel PC 6.2.1 Battery The lithium-ion battery powers the real-time clock and CMOS memory. It is an auxiliary source of power when the main power is shut off or disconnected. It is a standard CR2032 battery and is accessible on the bottom of the computing module when separated from the screen (as shown below) Safety Measures...
  • Page 128: I/O And Connectors

    PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 6.2.2 I/O and Connectors Outside I/O The rear panel I/O port arrangement consists of the following: 1 power button • 1 24V DC-in 3-pin power connector • 1 DP++ •...
  • Page 129 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 9. Apply dc power to the unit. During normal startup and operation, the LED status indicator displays as follows: a. Solid amber while the RXi - Industrial Display unit is starting up b.
  • Page 130 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 USB Ports The USB ports allow for data exchange between your computer and a wide range of simultaneously accessible external Plug and Play peripherals. The RXi – Panel PC is equipped with 2 onboard USB 3.0 ports (USB 0-1) in the small configuration with an additional 2 USB 2.0 ports (USB 4-5) in the large box configuration.
  • Page 131 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 Audio Rear Audio The system board is equipped with 2 audio jacks (Line-out and Mic-in). A jack is a one-hole connecting interface for inserting a plug. • Line-out Jack (Lime) This jack is used to connect a headphone or external speakers.
  • Page 132 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 Expansion Slots Micro SD Socket The micro SD socket allows you to install a micro SD card to expand available storage. LVDS LCD Panel Connector The system board lets you connect an LCD Display Panel with the LVDS LCD panel connector. This connector transmits video signals and power from the system board to the LCD Display Panel.
  • Page 133: Led Indicators

    PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 6.2.3 LED Indicators Operation Status LEDs (Screen) All RXi Industrial Displays have a tri-color LED built into the screen that visually indicates the operation status. LED State System State Amber, Solid Operating system starting Green, Solid...
  • Page 134: Rxi - Web Panel

    PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 RXi - Web Panel 6.3.1 Jumpers and Connectors Locations Setting Jumper Functions 1. Locate the SW1 Switch (Figure 103) and remove the display to access the switch. Figure 103: SW1 Switch Location Note: Before installing the Web Panel, please set the necessary functions following the •...
  • Page 135 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 Setting Jumper Functions (SW1) SW1: 2bit switching ON/OFF, used to set the recording and the starting mode of the Motherboard. UPGRADE NORMAL 1.BOOT_MODE1_S MODE MODE • Figure 104: Junction Function (SW1) Hardware...
  • Page 136 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 Socket Description Connecting Input Power (24V DC-in) To connect to power, follow these steps: 1. Verify that the power cable is not energized. 2. Loosen the screw clamps on the mating power connector.
  • Page 137: Usb Socket (Usb_Otg1/Usb1)

    PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 Figure 105: Power Socket (DN-IN1) 6.3.2 USB Socket (USB_OTG1/USB1) USB_OTG1: Conn. Mini-USB, B-Type Female, SMD-5P With DIP 4pin, used to load system firmware Figure 106: USB, LAN, and COM Ports USB_OTG1 Pin# Signal Name 5V_USB_OTG...
  • Page 138 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 USB1: Type-A connector, supports USB devices. USB_OTG1 Pin# Signal Name 5V_USB_HOST1 USBDN_DM1 USBDN_DP1 LAN Socket (LAN1) LAN 1: Conn. I/O Port, RJ45, 1000M, provide a solid RJ45 Ethernet Dock, GREEN denotes data transfer, and YELLOW verifies a connection to the Internet.
  • Page 139: Led Indicators Operation Status Leds (Screen)

    PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 SD-Card Socket (SD1) SD1: Socket, mini SD/TF Card, 9 pins, SMD, supports SD/TF Card devices. BAT1 Socket (BAT1) BAT1: BAT Socket, BS-10-A1B0J001, 20mm SMT, supports non-chargeable batteries. CR-2032 Backlight Board Socket (BTB_MAIN_TB572B_1) BTB_MAIN_TB-572B_1: Conn.
  • Page 140 PACSystems™ RXi Industrial Displays User Manual Section 6 GFK-3138E Nov 2022 Link Green, ON Link Status Activity Hardware...
  • Page 141: Installation And Mounting Information

    PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Section 7: Installation and Mounting Information Panel Cutout Dimensions 7.1.1 Industrial Monitor The RXi Industrial Monitor can be panel-mounted as presented in Section 7.2, Panel Installation Steps. A Type 4, Type 4X, or IP 66 rating is achieved when mounted to the flat surface of a sufficiently rated enclosure.
  • Page 142 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 All panel cutout measurements should be within ±0.5 mm The values presented are width and height only. Installation and Mounting Information...
  • Page 143: Panel Pc Cutout Dimensions

    PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 7.1.2 Panel PC Cutout Dimensions The RXi Panel PC can be panel-mounted as presented in Section 7.3, Mounting to Modular Display. A Type 4, Type 4X, or IP 66 rating is achieved when mounted to the flat surface of a sufficiently rated enclosure.
  • Page 144: Web Panel Cutout Dimensions

    PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 7.1.3 Web Panel Cutout Dimensions Figure 109: Panel Cutout Dimension Definitions Width Display Size (in) Width (mm) Height (mm) 183.5 128.5 255.5 214.5 245.5 Installation and Mounting Information...
  • Page 145: Panel Installation Steps

    PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Panel Installation Steps Verify that the gasket is present and properly seated in the bezel channel located on the sides of the unit Insert the unit into the mounting panel cutout Figure 110: Panel Install View Insert the hook of the mounting bracket into the mounting hole, as displayed in the following figure.
  • Page 146 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 4. Tighten all mounting brackets by hand until the gasket seal contacts the mounting surface uniformly. 5. In a cross pattern around the monitor, tighten all mounting clip screws to a torque of 13 to 13.9 in-lbs.
  • Page 147: Mounting To Modular Display

    PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Mounting to Modular Display Figure 113: 7" Mount Installation and Mounting Information...
  • Page 148 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 114: 10" Mount Installation and Mounting Information...
  • Page 149 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 115: 12" Panel Mount Installation and Mounting Information...
  • Page 150 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 116: 15" Panel Mount Installation and Mounting Information...
  • Page 151 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 117: 19"/24" Panel Mount Installation and Mounting Information...
  • Page 152 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 118: Panel PC with AMD Ryzen Mount Installation and Mounting Information...
  • Page 153: Vesa Mount

    PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 VESA Mount Figure 119: 7" VESA Mount Installation and Mounting Information...
  • Page 154 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 120: 10" VESA Mount Installation and Mounting Information...
  • Page 155 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 121: 12" VESA Mount Installation and Mounting Information...
  • Page 156 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 122: 15" VESA Mount Installation and Mounting Information...
  • Page 157 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 123: 19"/24" VESA Mount Installation and Mounting Information...
  • Page 158 PACSystems™ RXi Industrial Displays User Manual Section 7 GFK-3138E Nov 2022 Figure 124: Panel PC with AMD Ryzen VESA Mount CAUTION Tighten the mounting clip screws by hand until the gasket contacts the mounting surface • uniformly. Tighten the mounting clip screws to a torque of 8-10 kgf-cm using the specified sequence. Be sure •...
  • Page 159: Rxi2-Lp Ipc

    PACSystems™ RXi Industrial Displays User Manual Section 8 GFK-3138E Nov 2022 Section 8: Firmware Update Instructions for the RXi-Panel PC and RXi2-LP IPC The following Firmware Update requires the user to use a portable media storage device. Users can deploy to either a DVD or a USB stick. Deploy to DVD (Option 1) 1.
  • Page 160: Deploy To Usb Stick (Option 2)

    PACSystems™ RXi Industrial Displays User Manual Section 8 GFK-3138E Nov 2022 Deploy to USB Stick (Option 2) 1. Insert a blank USB drive into your computer. a. This process may erase any data stored on the USB drive. If your selected USB drive contains any important data, please create a backup of the files before proceeding.
  • Page 161 PACSystems™ RXi Industrial Displays User Manual Section 8 GFK-3138E Nov 2022 Figure 125: AX Directory. 2. Folder Options: In C:\Windows, the file properties of the release notes file are set to hidden; the user must change the file browsing settings in Folder Options to see the file. Figure 126: Folder Options Firmware Update Instructions for the RXi –...
  • Page 162 PACSystems™ RXi Industrial Displays User Manual Section 8 GFK-3138E Nov 2022 3. Revision check: The release notes file uses dates to publish each change. Figure 127: Release Notes Firmware Update Instructions for the RXi – Panel PC and RXi2 – LP IPC...
  • Page 163: Rxi Panel Pc Windows Activation Procedure

    PACSystems™ RXi Industrial Displays User Manual Section 9 GFK-3138E Nov 2022 Section 9: RXi Panel PC Windows Activation Procedure The preloaded Windows 10 IOT Enterprise image on Panel PC is not activated by default. The product key is on the rear of the Panel PC backing module to activate Windows 10 IOT Enterprise.
  • Page 164 PACSystems™ RXi Industrial Displays User Manual Section 9 GFK-3138E Nov 2022 Note: Ignore the error message – “Windows reported that your device's hardware has changed. Error code: 0xC004F211.” 1. Find the Product Key Sticker on the rear side of the Panel PC backing module, as shown in (Figure 129).
  • Page 165: Activate A Windows 10 Iot Enterprise Ltsc Device Using A Telephone

    PACSystems™ RXi Industrial Displays User Manual Section 9 GFK-3138E Nov 2022 4. The Windows 10 product key is now active. Activate a Windows 10 IoT Enterprise LTSC Device Using a Telephone 1. On the device, open a command prompt as the administrator. 2.
  • Page 166 PACSystems™ RXi Industrial Displays User Manual Section 9 GFK-3138E Nov 2022 5. After step 2, a message stating that the Product Key was installed successfully. Click OK to proceed. Figure 134: Windows Script Host 6. Press the Win+R keys to open Run, then type: SLUI 4 and click OK. Figure 135: Run the SLUI 4 Command Note: There is a space between SLUI and 4.
  • Page 167 PACSystems™ RXi Industrial Displays User Manual Section 9 GFK-3138E Nov 2022 7. Select your country or region and click Next. It navigates to the next page, where we can see the Installation ID. Figure 136: Select Country or Region 8. Call the Microsoft Product Activation Center. (The phone number is provided based on the selected region.) Proceed through the automated menu and answer a few questions about the Windows activation.
  • Page 168 PACSystems™ RXi Industrial Displays User Manual Section 9 GFK-3138E Nov 2022 10. The phone activation system will provide the user with a 48-digit Confirmation ID. Enter the Confirmation ID as seen in (Figure 138). Figure 138: Confirmation ID 11. Once the Confirmation ID has been entered, click the Activate Windows button. 12.
  • Page 169: Updating Firmware With Physical Access To Web Panel

    PACSystems™ RXi Industrial Displays User Manual Section 10 GFK-3138E Nov 2022 Section 10: Firmware Update Instructions for the RXi - Web Panel 10.1 Updating Firmware with Physical Access to Web Panel Note: These firmware steps are applicable for build versions R313 or earlier. 1.
  • Page 170 PACSystems™ RXi Industrial Displays User Manual Section 10 GFK-3138E Nov 2022 3. Connect a Micro USB Cable from your desktop/laptop PC (running the Windows operating system) to the web panel in the OTG port on the Web Panel. Figure 142: OTG Port Location 4.
  • Page 171 PACSystems™ RXi Industrial Displays User Manual Section 10 GFK-3138E Nov 2022 5. If a USB connection is detected, you will see the HID-Compliance device, as shown in the following picture, then click Start to update the Web Panel firmware. Figure 144: HID-Compliant Device Firmware Update Instructions for the RXi - Web Panel...
  • Page 172 PACSystems™ RXi Industrial Displays User Manual Section 10 GFK-3138E Nov 2022 6. Upon completing the update, you will see one under Successful Operations—Click Stop and Exit, then Power-off Web Panel. Figure 145: Successful Operations 7. Adjust SW1 1 back to Off for normal operation mode. Figure 146: SW1 Toggled to OFF Firmware Update Instructions for the RXi - Web Panel...
  • Page 173: Updating Firmware Remotely

    PACSystems™ RXi Industrial Displays User Manual Section 10 GFK-3138E Nov 2022 10.2 Updating Firmware Remotely Note: The following firwmare steps are applicable for build versions R32X or later. 10.2.1 Enabling SSH Server 1. Click the Setup button on the Homepage setup page or on the startup screen to access the System Setup page.
  • Page 174: Copying Firmware Files To The Web Panel

    PACSystems™ RXi Industrial Displays User Manual Section 10 GFK-3138E Nov 2022 10.2.2 Copying Firmware Files to the Web Panel The RXi Web Panel’s firmware image can be updated using SSH. 1. Use the OpenSSH command line version (preinstalled on Windows or Mac OS) for copying the files.
  • Page 175: Updating The Firmware After Copying Firmware Files

    PACSystems™ RXi Industrial Displays User Manual Section 10 GFK-3138E Nov 2022 3. Click on Login. 4. Drag and drop the firmware file to /tmp directory of Web Panel. Note: Firmware filename is RXi_Yocto_Linux_WebPanel_r32X.tgz or RXi_Yocto_Linux_WebPanel_No_EMRLogo_r32X.tgz) 5. Click OK to transfer the files. Figure 150: Transfer the files 10.3 Updating the Firmware after Copying Firmware Files...
  • Page 176 PACSystems™ RXi Industrial Displays User Manual Section 10 GFK-3138E Nov 2022 4. Enter the User: wpuser password. 5. Switch to the Admin user: wpadmin by running su wpadmin and entering the wpadmin password. Figure 152: Sudo admin 6. Switch to root by running the command: sudo -s. Figure 153: Switch to Root Firmware Update Instructions for the RXi - Web Panel...
  • Page 177 Nov 2022 7. Run Command: tar -mxvf /tmp/RXi_Yocto_Linux_WebPanel_r32x.tar -C /tmp/ Figure 154: Run Tar Command Note: If upgrading a Non-Emerson-branded Web Panel (a web panel without an Emerson log), then run the command: tar -mxvf /tmp/ RXi_Yocto_Linux_WebPanel_No_EMRLogo_r32X.tgz -C /tmp/ 8. Change the directory to /tmp/update: cd /tmp/update Figure 155: Change Directory 9.
  • Page 178: Appendix A: Open-Source Declaration

    Appendix A: Open-Source Declaration RXi Web Panel contains certain 3rd party (including “open source”) content, and Emerson makes the product available to you under the terms and conditions of the 3rd party license agreements governing such content. The copyright statements and licenses apply to various 3rd party content distributed with the Emerson product.
  • Page 179: General Contact Information

    Emerson reserves the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice. Emerson does not assume responsibility for the selection, use, or maintenance of any product.