NOTE:
A DC-powered router needs to be connected with the outdoor DC
power cord that is purchased from Juniper Networks, and which is
compatible with the ACX500 outdoor router. To supply sufficient power,
the DC input wiring on the facility DC source is capable of supplying at
least 5 A @–48 VDC per input for each power supply. We recommend
that the 48–VDC facility DC source should be equipped with a circuit
breaker rated at 5 A @–48 VDC minimum, or as required by local code.
For other nominal input voltages such as 24 VDC, –60 VDC, we recommend
that the circuit breaker rating be appropriately sized or rated, and as
required by local code.
Tighten the power cord plug screw.
6.
The power cord plug screw prevents water and dust from entering the terminal.
Verify that the power cabling is correct, that the power cables do not touch or block
7.
access to router components, and that they do not drape where people could trip on
them.
Observe the system LED on the router. If an DC power supply is functioning normally,
8.
the system LED lights green steadily.
If the system LED is not lit, the power supply is not functioning normally. Repeat the
cabling procedures.
ACX500 Power Overview on page 49
ACX500 DC Power Electrical Safety Guidelines on page 225
ACX500 General Electrical Safety Guidelines on page 219
Chapter 14: Providing Power to the ACX500
149