Equipment
Chemical bolts or Mechanical
Expanding bolts.
Standard Tools
References
Pre-installation procedure on page 33
Orienting and securing
Shim Drawing
Example of shim.
xx0700000623
3HAC030005-001 Revision: -
Action
1. Make sure the installation site for the robot conforms
to the specifications in section
procedure on page
33.
2. Prepare the installation site.
3. Use a Water level to level the robot cage.
4. Secure the robot cage to the floor.
2 Installation and Commissioning
2.4.4. Orienting and securing the robot cage
Spare/ Part No.
Note
Standard toolkit on page 196
Pre-installation
Continued
Note
Use shim for leveling. Example of
shim shown in
Shim Drawing on
page 45
Use Chemical or Mechanical
Expander bolts.
45