4. To reinstall, reverse the order of removal.

5.15 PH Unit

1. Remove the toner cartridge (C, M, Y, K).
F.5.1.1 Replacing the toner cartridge (C, M, Y, K)
2. Remove the waste toner bottle.
F.5.2.1 Replacing the waste toner bottle
3. Remove the imaging unit (C, M, Y, K).
F.5.1.2 Replacing the imaging unit (C, M, Y, K)
4. Remove the left cover.
G.5.2 Left cover
5. Remove the rear cover.
G.5.1 Rear cover
6. Remove the rear right cover.
G.5.3 Rear right cover
7. Remove the MFP board.
G.5.10 MFP board (MFPB)
8. Remove the printer control board.
G.5.11 Printer control board (PRCB)
9. Remove the high voltage unit.
G.5.13 High voltage unit (HV1)
[2]
[1]
CAUTION
• Do not replace the printer head unit while the power is
ON.
Laser beam generated during the above mentioned
activity may cause blindness.
• Do not disassemble or adjust the printer head unit.
Laser beam generated during the above mentioned
activity may cause blindness.
G DISASSEMBLING/REASSEMBLING > 5. Disassembly/reassembly
3. Unhook two tabs [1], and remove the SSD board [2].
10. Remove the screw [1], and remove the rail [2].
G-17